Saeco Intrnational Group
Page 3 / 14
TALEA / ODEA - LINE
04 FUNCTIONAL PRINCIPLES
Brewing unit pressure reduction:
Before the brewing unit moves to the home
position after a brewing process, the electric
valve opens and the overpressure in the brew-
ing chamber is released and escapes into the
residual water tray.
Silikonschlauch
Wasserauslaufstutzen
Pin
3-5 bar coffee dispensing valve
Release valve
16-19 bar safety valve
4.2.
Solenoid valve / multi-way valve
Silikonschlauch
Wasserauslaufstutzen
Pin
3-5 bar coffee dispensing valve
Release valve
16-19 bar safety valve
Ventilation:
After the appliance is switched on, the electric
valve opens, the pump is activated and the
appliance is ventilated automatically.
Preheating the pipes:
If the coffee machine has not been used for
a while or after each heating-up phase, the
pump is activated during the grinding process.
The hot water enters via the pipes, the multi-
way valve, and the water channel into the
residual water tray.
When coffee is dispensed:
The same applies for when coffee is dispensed,
only the brewing unit is positioned in the
brewing position and is docked to the pin.
Silikonschlauch
Wasserauslaufstutzen
Pin
3-5 bar coffee dispensing valve
Release valve
16-19 bar safety valve
from boiler
from boiler
to residual
water tray
to residual
water tray
to hot water /
steam valve
to hot water /
steam valve
from boiler
to residual
water tray
to hot water /
steam valve
18-20 bar safety valve
18-20 bar safety valve
18-20 bar safety valve
Summary of Contents for ODEA
Page 10: ...Saeco International Group Talea Odea Line CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Talea Odea Line CHAPTER 3 OPERATING...
Page 27: ...Saeco International Group Talea Odea Line CHAPTER 4 FUNCTIONAL PRINCIPLES...
Page 42: ...Saeco International Group Talea Odea Line CHAPTER 5 SERVICE MODALITY...
Page 77: ...CHAPTER 8 NOTES Saeco International Group Talea Odea Line...
Page 78: ...Saeco International Group Page 1 2 TALEA ODEA LINE 08 NOTES...
Page 79: ...Page 2 2 Saeco International Group 08 NOTES TALEA ODEA LINE...
Page 80: ...Saeco International Group Talea Odea Line CHAPTER 9 WATER SYSTEM DIAGRAMS...
Page 87: ...Saeco Internationa Group Talea Odea Line CHAPTER 10 WIRING DIAGRAMS...
Page 88: ...Odea Go...
Page 89: ......
Page 90: ...Odea Giro...
Page 91: ......
Page 92: ...Talea Giro Plus...
Page 93: ......
Page 94: ...Talea Ring...
Page 95: ......
Page 96: ...Talea Ring plus...
Page 97: ......
Page 98: ...Talea Touch Plus...
Page 99: ......