NEW ROYAL
05 TROUBLESHOOTING
Saeco International Group
Rev. 01
Page / 07
5.3. Error messages
Code
Brief description
Description
01
Coffee grinder blocked
The coffee grinder is blocked (grinder blades
jammed or sensor not reading properly)
03
Brewing unit blocked in ‘work’
position
Descent time-out exceeded
04
Brewing unit blocked in ‘home’
position
Ascent time-out exceeded
05
Water circuit blocked
No w
ater in fl ow meter or fl ow meter not turning
(jammed)
06
Frother unit solenoid valve
Frother unit solenoid valve short-circuit
07
Doser microswitch blocked
Doser microswitch short-circuit
10
Coffee boiler short-circuit
Coffee boiler temperature sensor short-circuit
11
Coffee boiler in open circuit
Coffee boiler temperature sensor in open circuit
12
Steam boiler short-circuit
Steam boiler temperature sensor short-circuit
13
Steam boiler in open circuit
Steam boiler temperature sensor in open circuit
14
Misc. temperature errors
(coffee boiler)
Coffee boiler temperatures out of control
15
Misc. temperature errors
(steam boiler)
Steam boiler temperatures out of control
16
Brewing unit short-circuit
Brewing unit microswitch short-circuit
17
Not used
18
Not used
19
No zero crossing
No zero crossing on card, could be caused by power
board
20
Not used