MINUTO 05 TROUBLESHOOTING
Page / 46
Start condition
Start condition
Press the ESPRESSO button to open the Electro Valve
Press the ESPRESSO button to open the Electro Valve
IMPORTANT NOTE: If the DREGDRAWER is not inserted or the DOOR is not
IMPORTANT NOTE: If the DREGDRAWER is not inserted or the DOOR is not
closed the EV test cannot be performed. If these 2 inputs are not in the
closed the EV test cannot be performed. If these 2 inputs are not in the
right position, a warning message will be shown and the display turns to
right position, a warning message will be shown and the display turns to
yellow.
yellow.
Press the STEAM button to switch on the pump
Press the STEAM button to switch on the pump
The water goes out from the pipe and the indication
The water goes out from the pipe and the indication
IMP
IMP
shows
shows
increasing numbers. The indication L/H must be within the range 10-18.
increasing numbers. The indication L/H must be within the range 10-18.
It is possible to hear the “click” from Electro Valve. The indication beside
It is possible to hear the “click” from Electro Valve. The indication beside
the
the
EV1
EV1
changes from “OFF” to “ON”.
changes from “OFF” to “ON”.
ERROR:
ERROR:
The display backlight changes from green to red and the
The display backlight changes from green to red and the
impulse remains 0; If water comes out the pipe: check the wiring from the
impulse remains 0; If water comes out the pipe: check the wiring from the
fl
owmeter to the CPU/POWER board (JP5). If no water comes out the pipe:
fl
owmeter to the CPU/POWER board (JP5). If no water comes out the pipe:
check the pump and the wiring from the pump to the CPU/POWER board
check the pump and the wiring from the pump to the CPU/POWER board
(JP24).
(JP24).
ERROR:
ERROR:
The L/H is zero or very low; the Electro Valve does not
The L/H is zero or very low; the Electro Valve does not
open. Check the wiring from the Electro Valve to the CPU/POWER
open. Check the wiring from the Electro Valve to the CPU/POWER
board (JP3) and the Electro Valve.
board (JP3) and the Electro Valve.
Press the STEAM button to switch on the grinder
Press the STEAM button to switch on the grinder
The grinder rotates and in the indication GRINDER the number
increasing up to 40. The other numbers inside the GRINDER box are not
important for this test.
ERROR:
ERROR:
The number remains 0 or the grinder does not run, the
The number remains 0 or the grinder does not run, the
display backlight changes from green to red; check the Hall sensor
display backlight changes from green to red; check the Hall sensor
board of the Grinder, the Grinder, the wiring from the Hall sensor
board of the Grinder, the Grinder, the wiring from the Hall sensor
board to the CPU/POWER board (JP2) and the wiring from the
board to the CPU/POWER board (JP2) and the wiring from the
Grinder to the CPU/POWER board (JP8)
Grinder to the CPU/POWER board (JP8)
Initial status
Initial status
20
Operational check - solenoid valves and pump
Press STAND_BY “
Press STAND_BY “
” to move to the next screen
” to move to the next screen
Operational check - coffee grinder and boiler
Summary of Contents for Minuto
Page 3: ...MINUTO CHAPTER 1 INTRODUCTION...
Page 10: ...MINUTO CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 16: ...MINUTO CHAPTER 3 USER INSTRUCTIONS...
Page 30: ...MINUTO CHAPTER 4 OPERATING LOGIC...
Page 41: ...MINUTO CHAPTER 5 TROUBLESHOOTING...
Page 88: ...MINUTO CHAPTER 6 STANDARD CHECKS...
Page 91: ...MINUTO CHAPTER 7 DISASSEMBLY...
Page 101: ...MINUTO CHAPTER 8 NOTES...
Page 102: ...MINUTO 08 NOTES Page 01 01...
Page 103: ...MINUTO CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 107: ...MINUTO CHAPTER 10 ELECTRICAL DIAGRAM...
Page 108: ...MINUTO 10 WIRING DIAGRAM Page 02 01 Minuto Cappuccino Focus and Class...
Page 109: ...MINUTO 10 WIRING DIAGRAM Page 02 Minuto Pure 02...