30
English
SYSTEM MANAGEMENT
VM CODE
000000
VM CODE
>000000<
STOPS
STOP COFFEE
00000 LIM:00321
STOP BEVERAGES
RESET
MIN. TEMPERATURE
098
MIN. TEMPERATURE
>096<
MAX. TEMPERATURE
108
MAX. TEMPERATURE
>110<
RINSING CYCLE
NO
RINSING CYCLE
Y >N<
PREGRINDING
NO
PREGRINDING
Y >N<
CONTINUES
8.2.3
Description of messages in
the programming menu
Important
Visible only if the complete menu option is
enabled
Important
The menu items are visible only if the option “Complete menu”
is enabled and will be marked with the (“CM”) abbreviation.
SYSTEM MANAGEMENT
The SYSTEM MANAGEMENT items are:
- VM Code
Enables an identification code to be assigned to the
vending machine.
- Stops (“CM”)
Enables setting of the maximum amount of beverage or
coffee. Once the maximum amount is reached, the
vending machine stops dispensing the relevant
beverages. The first digit on the left (“00000”) refers to
the quantity of product dispensed since the last “RESET”
(partial counters).
The right hand digit, preceded by “LIM”, shows the
maximum dispensable quantity (value may be modified).
• Stop coffee
Enables setting of the maximum number of coffee cups
to be dispensed before the stop.
• Stop beverages
Enables setting of the maximum number of beverages to
be dispensed before the stop.
• Reset
Enables resetting of all partial counters relative to product
quantity stop functions.
- Step down counters
It allows setting a quantity of water which must be
dispensed before the message of operation in the
maintenance menu is received.
In the menu item, the value on the left (00150) shows
the quantity of water that may be still dispensed, whereas
the value on the right (LIM:00150) shows the set limit.
The quantity is expressed approximately in litres.
By dispensing water (for beverages or rinses) the counter
on the left is decreased. When the value “0” is reached,
the new item “STEP DOWN COUNTERS” will be
displayed in the maintenance menu (WARNING 83 will
be registered in the ERROR LOG).
- Min. temperature
Enables setting of the temperature to be maintained for
a few minutes by the vending machine after a beverage
has been dispensed. The set value is expressed in
centigrade.
- Max. temperature
Enables setting of the temperature to which the vending
machine is brought after a certain time from the last
dispensing, in order to compensate for the natural
decrease of the temperature of the hydraulic circuits.
The set value is expressed in centigrade.
- Rinsing Cycle
It allows enabling of the automatic rinsing of the mixing
bowls. The automatic rinsing is performed as follows:
the first rinsing takes place 10 minutes after the “machine
ready” status; if necessary, other rinses occur 7 hours
after the last dispensing.
- Pre-grinding
Enables instant pre-grinding of the coffee dose.
STEP DOWN COUNTERS
RESINS REGENERATION
00150 LIM:00150
RESET
Y >N<