ROYAL
6. FAULTS
Saeco International Group
REV.4 SEPT.2003
Page 1/3
1. Faults:
The following table indicates the most common faults, listed by component.
Part
Fault
Cause
SI on mains filter defective
Main switch defective
Door switch defective
Electronic system defective
E
le
ct
ro
n
ic
s
Does not function
No display
KTY defective
Cold coffee
Standby LED lights up
continuously
Electronic system defective
KTY defective
Temperature differences
No froth
Electronic system defective
Heating - Interruption
Heating plug connection
Thermal fuse
H
ea
ti
n
g
Heating remains cold
Heating indicator remains lit up
Fusible cut-out
(No grinder function)
Doser switch constantly
activated / Dirt
Water instead of coffee
Defective doser rinse
Dose quantity too low
Weak coffee
Dose chamber - coffee residues
Doser switch does not work
Doser flap does not close
D
o
se
r
Recurring indicator
COFFEE BEANS LOW
-
Brewing unit overfull
-
Gearmotor obstructed
Electronic system defective