5. SERVICE PROGRAMME
ROYAL
Page 6/24
REV.4 SEPT.2003
Saeco International Group
Function
Setting range
Increment
Comments
TEMP. INCREASE
°C 10
0-50°C
+/-1
The boiler temperature is increased
by a set value shortly before
brewing in order to pre-heat the
boiler. and compensate for the
temperature drop during the first
water flow.
GRINDS COUNTER
Number
0-50
+/-1
Counts number of coffee cycles.
When this value reaches the
Grinds Stop value, "GRINDS
CONTAINER EMPTY" will be
displayed. (Reset by removing
dregs drawer for emptying - min. 6
sec.)
GRINDS STOP
30
5-50
+/-1
Number of cycles until "EMPTY
GRINDS CONTAINER" is
displayed.
--TOTAL WATER--
(ml) Number
---------------------
------------------
-----
Total water flow volume (in ml) /
not resettable
WATER DESCALING
(ml)
---------------------
------------------
-----
Total water flow (in ml) since last
descaling / resettable
HOT WATER
FLOW (l/h) 20
6 - 34 1/h
+/- 2 1/h
The
pump delivery rate
for hot
water can be expressed in litres per
hour.
--HOT WATER---
PUMP ADJUST. 63000
58,000 - 65,500
+/- 1
The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
MACHINE STATUS
0 - 255
36
--DATE OF MANUF---
DAY
---------------------
------------------
-----
--DATE OF MANUF---
MONTH
---------------------
------------------
-----
--DATE OF MANUF---
YEAR
---------------------
------------------
-----
This date indicates when the
machine was manufactured. This
date cannot be changed.
--SERVICE DATE--
DAY
0 - 31
+/- 1
--SERVICE DATE--
MONTH
0 - 12
+/- 1
--SERVICE DATE--
YEAR
1996 - 2050
+/- 1
The service date indicates the date
of the machine's last service. This
date can be changed and must be
updated at each service.
Exit:
Switch the machine off at the main switch or by pressing ESC twice.
Summary of Contents for Cappuccino
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 16: ......
Page 18: ......
Page 44: ......
Page 46: ......
Page 70: ......
Page 95: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 6 FAULTS Page 1 Faults 1...
Page 96: ......
Page 100: ......
Page 102: ......
Page 116: ......
Page 120: ......
Page 141: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 10 CIRCUIT DIAGRAMS...
Page 142: ......
Page 143: ......