PROBLEm

CAUSE

REmEDY

Machine switch off

1. Mains switch off

1. position the machine switch to position ON

2. Machine switch off

2. position the machine switch to position 1

3. Incorrect electrical mains connection

3. contact specialized personnel in order to che-

ck the connection

No water in boiler

1. Mains tap closed

1. open the mains tap

2. Clogged pump filter

2. replace the filter

3. Motor driven pump not in operation

3. contact specialized personnel

No unit delivery

1. mains tap closed

1. open the mains tap

2. motor driven pump out of order

2. contact specialized personnel

3. clogged gigleur

3. contact specialized personnel

4. burnt control box fuse

4. contact specialized personnel

5. unit solenoid valve out of order

5. contact specialized personnel

6. unit switch out of order

6. contact specialized personnel

Steam fails to come out of the nozzle

1. too much water in boiler

1. see specific problem

2. damaged resistance

2. contact specialized personnel

3. clogged sprayer element

3. clean the sprayer element

4. resistance saver engaged

4. reinsert the resistance

Too much water in the boiler

1. the motor driven pump remains engaged

1. contact specialized personnel

2. perforated exchanger

2. contact specialized personnel

3. automatic charge solenoid valve blocked

3. contact specialized personnel

Signs of water leakage on bench

1. dirty drain tray

1. clean the try

2. drainage pipe clogged or detached

2. replace the drainage pipe

3. other leakage

3. contact specialized personnel

Wet coffee dregs

1. Grinding regulated too fine

1. Adjust grinding value

2. Unit still cold

2. wait for the machine to reach the correct 

temperature

3. Solenoid valve fails to discharge

3. contact specialized personnel

Coffee dispensing too slow

1. grinding element set too fine

1. Adjust the grinder

2. dirty filter-holder

2. replace the filter and undertake more frequent 

filter-holder cleaning

3. clogged unit

3. contact specialized personnel

4. gigleur or solenoid valve partially clogged

4. contact specialized personnel

Coffee dispensing too fast

1. grinder is regulated too large

1. regulate the grinding

Coffee delivered cold

1. Lime scale present on the exchangers or the 

resistances

1. contact specialized personnel

2. oxidized pressure switch contacts

2. contact specialized personnel

3. defective electrical connection

3. contact specialized personnel

4. partially burnt out resistance

4. replace the resistance element

Coffee delivered too hot

1. incorrect pressure switch calibration

1. regulate the pressure switch by means of the 

relative screw (chap. 6.2)

Summary of Contents for AROMA COMPACT SE

Page 1: ...maschine M quina Profesional para Caf Expr s Professionele machine voor espressokoffie M quina profissional para caf expresso Modello Model Mod le Modell Modelo Modellen Modelos AROMA COMPACT SM USO E...

Page 2: ...misura Sezione 6 Immunit ai disturbi condotti indotti da campi a radiofrequenza EN61000 4 6 Compatibilit elettromagnetica EMC Parte 4 Tecniche di prova e misura Sezione 11 Prove di immunit a cadute d...

Page 3: ...NSEGUENZA A COMPILARE IL MODELLO ALLEGATO 1 VEDI ULTIME PAGINE DI QUESTO MANUALE IN DUPLICE COPIA E A SPEDIRLO ALLE SEDI DI COMPETENZA TERRITORIALE ASL E ISPESL N B La mancata comunicazione pu comport...

Page 4: ...ns le pr sent manuel nous sommes certains que vous appr cierez la qualit de notre machine Nous vous prions de lire attentivement les indications contenues dans le manuel sur l utilisation correcte de...

Page 5: ...ions particuli rement importantes et ou dangereuses Atenci n Operaciones particularmente importantes y o peligrosas Let op Bijzonder belangrijke en of gevaarlijke werkzaamheden Aten o Opera es particu...

Page 6: ...ch adjustment 31 6 3 Pump pressure calibration 31 6 4 Filters for coffee machine 32 6 5 Replacement of the thermostat to reduce the coffee dispensing group temperature 32 6 6 With spouts 32 7 FUNCTION...

Page 7: ...rder to provide advice on cor rect use cleaning and regulation It also provides important maintenance information and details on any residual risks and all those operations which require particular ca...

Page 8: ...ower supply cable is in good conditions Damaged cables must never be repaired using insulating tape or clamps Do not expose the machine to the elements sun rain etc Prolonged machine standstill at tem...

Page 9: ...530 L 540 540 Weight kg 37 43 Boiler capacity L 4 9 4 9 Boiler resistance absorbed power 230 240 V W 2730 2730 ECO Max boiler resistance absorbed power 230 240 V W 1820 1820 Pump motor W 165 165 Over...

Page 10: ...ion Check that the power supply cable is efficient and that it complies with national and European safety standards The user must undertake to power the machine protecting the power line using a suita...

Page 11: ...t for the pressure to reach its operational pressure 1 1 1 3 atm checking the boiler pressure on the gauge 6 Should the machine fail to stabilize on the indicated values it is necessary to calibrate t...

Page 12: ...Disconnect the electricity supply before undertaking this operation fig 5 fig 6 fig 7 6 3 Pump pressure calibration Insert the filter holder into the unit filled with regularly ground dosed and presse...

Page 13: ...ces 6 5 Replacement of the thermostat to reduce the coffee dispensing group temperature Remove cup heating bowl 1 Disconnect group thermostat 2 Code WGADM1561 T 103 C and replace it with the lower tem...

Page 14: ...measure to be programmed key T1 for example within 30 seconds programming time out The led relative to T5 will remain on on all keyboards and the led relative to the measure being programmed will also...

Page 15: ...chine units To proceed with a new programming operation of other coffee measures T2 T3 T4 providing that the programming time out time of 30 sec is not exceeded simply repeat the same operations with...

Page 16: ...tained by pressing it a second time Engagement deactivation Start the machine by pressing the main switch keeping key T5 of unit 1 pressed and wait for the led relative to key T5 to begin flashing Pre...

Page 17: ...n on again Lack of volumetric counter impulses On starting a volumetric control coffee cycle the correct function of the volumetric counter is checked by the reading of the number of impulses sent by...

Page 18: ...lever from right to left as shown in fig 11 3 and allow the salted water to drain out of pipe F until the water is fresh Shift lever D from right to left as shown in fig 11 4 NB These regeneration in...

Page 19: ...y coffee deposits which may jeopardize yield we advise that before starting work in the morning that you put filter holder D in with empty filter while machine is hot and operate the unit several time...

Page 20: ...he boiler 1 the motor driven pump remains engaged 1 contact specialized personnel 2 perforated exchanger 2 contact specialized personnel 3 automatic charge solenoid valve blocked 3 contact specialized...

Page 21: ...itch Schalter Kaffee Interrupteur du caf Interruptor caf Schakelaar koffie Interruptor caf 12 Elettrovalvola gruppo unit solenoid valve Magnetventil Gruppe lectrovanne du groupe Electrov lvula grupo M...

Page 22: ...tion about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Dieses Produkt entspricht der EU Richtlinie...

Page 23: ...nties het bedrijf of de dienst belast met de verwijdering van huishoudafval of de winkel waar u het product hebt gekocht NL Este produto est conforme a directiva EU 2002 96 EC O simbolo impresso no pr...

Page 24: ...Cod WGA8011011000 Rev 05...

Reviews: