5
SENT Gateway Analyser
The SENT Gateway Analyser is a Windows application that provides the user an easy way to use the
gateway. The application is provided free-of-charge and allows to configure SENT channels and
analogue output channels, save and load the runtime and non-volatile configuration, and receive and
transmit Fast and Slow SENT messages.
5.1
Connection
5.1.1
SENT-RS232
Make sure your computer has an on-board COM port or a USB-COM adapter.
Default Communication Parameters:
Parameter
Value
Note
Baud Rate
115200 Baud
Data bits
8
not configurable
Parity
None
not configurable
Stop bit
1 bit
not configurable
Table 5 SENT-RS232 Default Communication Parameters
5.1.2
SENT-CAN
The SENT Gateway application works with CAN interfaces by Kvaser (
). Therefore, a
Kvaser interface is needed in order to use the application.
Make sure that Kvaser driver is installed on your computer.
Select CAN channel, baud rate and CAN ID for both directions.
Default Communication Parameters:
Parameter
Value
Baud Rate
500 KBaud
PC TX CAN Id 0x123 (Standard)
PC TX CAN Id 0x321 (Standard)
Table 6 SENT-CAN Default Communication Parameters