![Sacmi Imola CHS100 Instructions Manual Download Page 32](http://html1.mh-extra.com/html/sacmi/imola-chs100/imola-chs100_instructions-manual_795368032.webp)
CHS100.86.011 Rev.02 Date 23/07/2018
32
2022 FIRST CONVEYOR BELT REJECT CHECK CONTAINER PRESENT CHECK (SQ9B)
(STOPPAGE)
The first conveyor belt reject check container was not detected or not in the correct position
during the automatic cycle.
Make sure photocell SQ9B is in the correct position and is properly set.
2023 SECOND CONVEYOR BELT REJECT CONTAINER PRESENT CHECK (SQ9C)
(STOPPAGE)
The second conveyor belt reject container was not detected or not in the correct position
during the automatic cycle.
Make sure photocell SQ9C is in the correct position and is properly set.
2024 SECOND CONVEYOR BELT REJECT CHECK CONTAINER PRESENT CHECK
(SQ9D) (STOPPAGE)
The second conveyor belt reject check container was not detected or not in the correct
position during the automatic cycle.
Make sure photocell SQ9D is in the correct position and is properly set.