SHUTDOWN MESSAGES
1001 EMERGENCY STOP BUTTON (SHUTDOWN)
An emergency stop button on the machine or along the line may have been pressed.
If this is not the case, verify the emergency device to which the button is connected works
properly.
Make sure the emergency stop buttons are properly connected and work correctly.
1002 CHECK COMPRESSED AIR (SP1) (SHUTDOWN)
The compressed air pressure measured is too low in order for the machine to operate
correctly.
Input SP1 is open. Check the pressure actually present in the circuit under normal work
conditions.
If the above mentioned condition is not present, make sure the device is properly connected
and works efficiently.
1003 CHECK CAP OUTFEED IN THE FIRST CONVEYOR BELT (SQ11) (SHUTDOWN)
No caps were detected in front of photocell SQ11 during the automatic cycle.
SQ11 input is permanently off or on.
Make certain sensor SQ11 is in the correct position and works properly.
1004 CHECK CAP OUTFEED IN THE OVERTURNED CONVEYOR BELT (SQ11B)
(SHUTDOWN)
No caps were detected in front of photocell SQ11B during the automatic cycle.
SQ11B input is permanently off or on.
Make certain sensor SQ11B is in the correct position and works properly.
1005 CHECK CAP INFEED IN THE FIRST CONVEYOR BELT (SQ53) (SHUTDOWN)
No caps were detected in front of photocell SQ53 during the automatic cycle.
SQ53 input is permanently off or on.
Make certain sensor SQ53 is in the correct position and works properly.
1006 CHECK CAP INFEED IN THE OVERTURNED CONVEYOR BELT (SQ53B)
(SHUTDOWN)
No caps were detected in front of photocell SQ53B during the automatic cycle.
SQ53B input is permanently off or on.
Make certain sensor SQ53B is in the correct position and works properly.
1007 CHECK SPACER INVERTER (U13) (SHUTDOWN)
Drive U13 shutdown was detected. Make sure there are no faults in the drive.
Make certain there are no mechanical obstructions that impede motor M13 from working
properly.
1008 CHECK INVERTER IN THE FIRST CONVEYOR BELT (U15) (SHUTDOWN)
Inverter U15 shutdown was detected. Make sure there are no faults in the drive.
Make certain there are no mechanical obstructions that impede motor M15 from working
properly.