Sabre Vision 3 User Instructions Download Page 9

VISION 3 

4.  DON APPARATUS 

4.1  ATTACH DEMAND 

VALVE 

1. 

Check  that  the 

VISION  3

  head-

harness  is  fully  slackened  and  that  the 

DV is connected to the facemask. 
2. 

Place  the  neck-strap  round  the 

neck. 

 

3. 

Check  that  the  flat  on  the  DV 

bypass  knob  is  off  (flat  on  the  knob  is 

towards the facemask). 
4. 

Press the black reset button. 

5. 

Follow  the  appropriate  breathing 

apparatus’  user  instructions  to  supply air 

to the facemask. 

4.2  DON FACEMASK 

4.2.1 

Facemasks with a Web 

Harness 

 

1. 

Hold  the  head-harness  lower 

straps,  place  chin  in  chin-cup  and  pull 

straps  over  back  of  head,  brushing  hair 

away from faceseal. 

 

2. 

Adjust  the  facemask  top  strap  so 

that  the  mask  is  at  the  correct level with 

the  face  and  the  head-harness  pad  is  in 

the  centre  of  the  back  of  the  head,  then 

tighten  harness  straps  in  sequence: 

Bottom,  Middle,  Top

.  DO  NOT  over-

tighten. 

4.2.2 

Facemasks with a Net 

Harness 

 

1. 

Hold  the  mask  by  the  side  of  the 

net harness, place the chin into the chin-

cup  and  pull  the  mask  onto  the  face. 

Grasp the pull-strap at the rear of the net 

harness and pull the net over the head. 

 

Summary of Contents for Vision 3

Page 1: ...VISION 3 Positive Pressure Facemask User Instructions Article No 1074216 Issue C 10 2004...

Page 2: ...Facemasks 5 3 3 POSITIVE PRESSURE TEST 5 3 4 BREATHING APPARATUS TESTS 5 4 DON APPARATUS 6 4 1 ATTACH DEMAND VALVE 6 4 2 DON FACEMASK 6 4 2 1 Facemasks with a Web Harness 6 4 2 2 Facemasks with a Net...

Page 3: ...not be provided in certain highly toxic atmospheres The apparatus must be tested and serviced in accordance with Section 7 Scheduled Maintenance and the notes in Section 1 under Training and Servicing...

Page 4: ...conform to EN 12021 1999 and must have a dew point sufficiently low to prevent internal freezing when apparatus is used in temperatures below 4 C No of Wearers Airflow L min 1 2 3 4 300 450 750 900 Ta...

Page 5: ...the appropriate Service Manual copies of which can only be obtained by registered holders of a current certificate Your Sabre distributor or Training and Technical Support Services will be pleased to...

Page 6: ...d breathing apparatus approved to EN 137 and compressed air airline breathing apparatus approved to EN 139 VISION 3 is approved to EN 136 1998 CL 3 and is CE marked in accordance with EEC Directive EC...

Page 7: ...Fit the DV of a breathing or airline apparatus for which VISION 3 is approved to the facemask Note If VISION 3 is to be used with RAS fit filter and filter cover after first ensuring that the filter a...

Page 8: ...tes 3 3 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten se...

Page 9: ...4 2 1 Facemasks with a Web Harness 1 Hold the head harness lower straps place chin in chin cup and pull straps over back of head brushing hair away from faceseal 2 Adjust the facemask top strap so th...

Page 10: ...emove finger and allow mask to re seal 4 4 FACEMASK SEAL TEST 1 Close the cylinder valve and keep hold of the handwheel Hold breath for 10 seconds and listen carefully for leaks A leak will cause the...

Page 11: ...light prior to storage 1 Disconnect DV from the facemask 2 Wash and disinfect the mask thoroughly in a solution of TriGene TM and warm water See following Note 3 Rinse the mask thoroughly in clean run...

Page 12: ...C 7 SCHEDULED MAINTENANCE 7 1 MONTHLY Carry out tests on VISION 3 in accordance with Section 3 Pre use and Monthly Checks Record test details in the apparatus BA Logbook This record is mandatory in t...

Page 13: ...Sabre Breathing Apparatus...