Please Read Carefully and Fully Understand

 

This  manual  is  for  use  by  personnel  trained  in  the  use  and  care  of  compressed  air 

breathing apparatus, and MUST NOT be used as a self-teaching guide by untrained users. 

Failure to understand or adhere to the 

VISION 3

 user instructions may result in injury or 

death. 

Scott Health and Safety Limited

 have taken great care to ensure that the information in 

this manual is accurate, complete and clear. However, 

Training and

 

Technical Support 

Services

  will  be  pleased  to  clarify  any  points  in  the  manual  and  answer  questions  on 

Sabre 

breathing apparatus. 

The  following  warnings  are  in  accordance  with  certifying  authority  requirements 

and apply to the use of breathing apparatus in general: 

 

Breathing apparatus users must be fully trained in the use and care of self-

contained, compressed air breathing apparatus. 

 

Ensure  that  the  selection  of  the  apparatus  type  is  sufficient  for  the  tasks 

being undertaken and the hazards likely to be encountered. Please refer to 

National Regulations for guidance. 

 

Adequate  protection  may  not  be  provided  in  certain  highly  toxic 

atmospheres. 

 

The apparatus must be tested and serviced in accordance with Section 7 - 

Scheduled  Maintenance

  and  the  notes  in  Section  1  under 

Training 

and

 

Servicing

 

The quality of air used to supply and charge breathing apparatus must meet 

the requirements of EN 12021 : 1999. See Section 1 for details. 

 

Ensure  that  a  good  seal can be obtained between the face and facemask. 

The  wearing  of  beards,  side-burns  or  spectacles  may  adversely  affect  the 

sealing of a facemask to the wearer's face. 

 

The apparatus is not designed for use underwater. 

 

 

The harness must not be used as a vehicle seat restraint 

 

 

Ensure  that  you  are  familiar  with  the  Warnings,  Cautions  and  Limitations 

contained in the user instructions for apparatus to be used with VISION 3. 

 

 

VISION  3  will  only  provide  the  Class  3  respiratory  protection  described in 

EN 136 : 1998 when used with an apparatus for which it is approved. 

DISCLAIMER 
Failure  to  comply  with  these  instructions  or  misuse  of  the  apparatus  may  result  in: 

death, injury or material damage, and invalidate any warranty or insurance claims. 

COPYRIGHT 

This manual must not be copied in part or whole, or used for purposes other than its intended 

purpose without the written permission of 

Scott Health and Safety Limited

 

Summary of Contents for Vision 3

Page 1: ...VISION 3 Positive Pressure Facemask User Instructions Article No 1074216 Issue C 10 2004...

Page 2: ...Facemasks 5 3 3 POSITIVE PRESSURE TEST 5 3 4 BREATHING APPARATUS TESTS 5 4 DON APPARATUS 6 4 1 ATTACH DEMAND VALVE 6 4 2 DON FACEMASK 6 4 2 1 Facemasks with a Web Harness 6 4 2 2 Facemasks with a Net...

Page 3: ...not be provided in certain highly toxic atmospheres The apparatus must be tested and serviced in accordance with Section 7 Scheduled Maintenance and the notes in Section 1 under Training and Servicing...

Page 4: ...conform to EN 12021 1999 and must have a dew point sufficiently low to prevent internal freezing when apparatus is used in temperatures below 4 C No of Wearers Airflow L min 1 2 3 4 300 450 750 900 Ta...

Page 5: ...the appropriate Service Manual copies of which can only be obtained by registered holders of a current certificate Your Sabre distributor or Training and Technical Support Services will be pleased to...

Page 6: ...d breathing apparatus approved to EN 137 and compressed air airline breathing apparatus approved to EN 139 VISION 3 is approved to EN 136 1998 CL 3 and is CE marked in accordance with EEC Directive EC...

Page 7: ...Fit the DV of a breathing or airline apparatus for which VISION 3 is approved to the facemask Note If VISION 3 is to be used with RAS fit filter and filter cover after first ensuring that the filter a...

Page 8: ...tes 3 3 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten se...

Page 9: ...4 2 1 Facemasks with a Web Harness 1 Hold the head harness lower straps place chin in chin cup and pull straps over back of head brushing hair away from faceseal 2 Adjust the facemask top strap so th...

Page 10: ...emove finger and allow mask to re seal 4 4 FACEMASK SEAL TEST 1 Close the cylinder valve and keep hold of the handwheel Hold breath for 10 seconds and listen carefully for leaks A leak will cause the...

Page 11: ...light prior to storage 1 Disconnect DV from the facemask 2 Wash and disinfect the mask thoroughly in a solution of TriGene TM and warm water See following Note 3 Rinse the mask thoroughly in clean run...

Page 12: ...C 7 SCHEDULED MAINTENANCE 7 1 MONTHLY Carry out tests on VISION 3 in accordance with Section 3 Pre use and Monthly Checks Record test details in the apparatus BA Logbook This record is mandatory in t...

Page 13: ...Sabre Breathing Apparatus...