VISION 3
8
5. DOFFING THE
APPARATUS
WARNING:
DO NOT remove apparatus until well
clear of the hazardous area.
1.
Hold breath and press the DV reset
button.
2.
Release the head-harness by
pulling the harness buckles forwards.
Remove mask and let it hang from the
neck-strap.
3.
Close the air supply valve and
follow the
After Use
instructions for the
air supply apparatus.
4.
Clean and test
VISION 3
as
described in
Section 6
.
6. AFTER USE
6.1 CLEANING
CAUTION:
•
USE
ONLY
the
specified
methods and materials. DO NOT
use bleach, solvent, detergent or
abrasive cleaners.
•
Dry thoroughly, away from direct
heat and sunlight, prior to
storage.
1.
Disconnect DV from the facemask.
2.
Wash and disinfect the mask
thoroughly in a solution of
TriGene
TM
and
warm water. See following
Note
.
3.
Rinse the mask thoroughly in clean
running water. Pay particular attention to
flushing out the exhale valve.
4.
Hang mask by its neckstrap and
allow it to dry thoroughly away from direct
heat or sunlight.
5.
When dry, wipe facemask seals
with
TriGene
TM
disinfectant wipes.
6.
Polish the visor inside and out with
a clean, lint-free cloth and slacken the
head-harness, ready for use.
Note:
TriGene
TM
is available from
Scott Health
and Safety Limited
in 1 litre and 5 litre
containers under Article Numbers
2008247 and 2008248 respectively.
Pump dispensers are available for the
above under Article Numbers 1017672 (1
litre) and 1017670 (5 litres).