background image

 

 

 

Code 

Description 

MG-16 

MG-24 

MG-36 

MG-48 

MG-60 

  Griddle 

plate     

20129087001  20129088001 

20129089001 

20129090001 

20129091001 

2    knob     

301110274 

301110274 

301110274 

301110274 

301110274 

3    oil pan     

20129087008  20129087008 

20129087008 

20129087008 

20129087008 

4    pilot     

302130019 

302130019 

302130019 

302130019 

302130019 

5    gas valve     

302220059 

302220059 

302220059 

302220059 

302220059 

6    foot     

302090047 

302090047 

302090047 

302090047 

302090047 

7    burner assy      302130363 

302130363 

302130363 

302130363 

302130363 

  inlet gas 

pipe     

302201568 

302201569 

302201570 

302201571 

302201572 

9  Pilot gas pipe 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code 

Description 

MG-16T 

MG-24T 

MG-36T 

MG-48T 

MG-60T 

  Griddle 

plate     

20129087001  20129088001 

20129089001 

20129090001 

20129091001 

2    knob     

301110274 

301110274 

301110274 

301110274 

301110274 

Summary of Contents for MG-16

Page 1: ...chased equipment Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty Please keep it for future reference after installation and do not throw it away This is a universal installation and operation instruction book which would apply to different models PLEASE READ ...

Page 2: ...burner do not use a telephone within close proximity Never attempt to move grates while cooking SET UP 1 Remove all packing material and tape as well as any protective plastic from the equipment 2 Place the equipment in the desired position and height 3 Install the four 4 legs onto the equipment 4 Clean and dry the equipment thoroughly before using INSTALLATION The installation of this equipment m...

Page 3: ...ncoming line pressure The regulator can only withstand a maximum pressure of PSI 14 WC If the line pressure is beyond this limit a step down regulator before the regulator provided will be required The arrow above FLOW shows gas flow direction and should point downstream to the equipment PROPANE GAS CONVERSION This griddle plate is shipped from the factory equipped with fixed burner orifices for n...

Page 4: ...ipment is normal This is a result of the painted coating burning off Allow the equipment to burn in for at least 20 minutes before the first use Pilot Flame Height Adjustment The pilot flame on the equipment has been factory adjusted When adjustment is necessary adjust the pilot flames as small as possible but high enough to light the burner immediately when the burner valve is turned to the highe...

Page 5: ... a certain size and installed to provide a supply of gas sufficient to meet the full gas input of the equipment A manual shut off valve should be installed upstream from the manifold within 4 ft 1 2m of the equipment and in a position where it can be reached in the event of an emergency Check entire gas piping system for leaks every so often Using a gas leak detector or soapy water solution is rec...

Page 6: ... tends to cling to griddle foods giving them a highly unsatisfactory and unappetizing appearance To keep the griddle clean and operating at peak efficiency follow these procedures AFTER EACH USE Clean the griddle with a wire brush of flexible spatula ONCE PER DAY Thoroughly clean the griddle back splash sides and front Remove empty and wash the grease drawer in the same manner as an ordinary cooki...

Page 7: ...blowing pilot out Call for service 4 Low gas pressure Call for service Fat appears to smoke excessively 1 Temperature set too high 2 Moisture in food may be turning into steam Food sticks to griddle or burned around edges 1 Temperature set too high 2 Griddle surface requires cleaning and or seasoning 3 Surface under food not covered with enough cooking oil Food under cooked inside 1 Temperature se...

Page 8: ...dividual control Natural Gas 4 0 W C 120 000 MG 60 5 Burners w individual control Natural Gas 4 0 W C 150 000 MODEL STYLE Thermostatic GAS TYPE MANIFOLD PRESSURE Total B T U per Hour MG 16T Single Burner Natural Gas 4 0 W C 30 000 MG 24T 2 Burners w individual control Natural Gas 4 0 W C 60 000 MG 36T 3 Burners w individual control Natural Gas 4 0 W C 90 000 MG 48T 4 Burners w individual control N...

Page 9: ...02130019 302130019 302130019 5 gas valve 302220059 302220059 302220059 302220059 302220059 6 foot 302090047 302090047 302090047 302090047 302090047 7 burner assy 302130363 302130363 302130363 302130363 302130363 8 inlet gas pipe 302201568 302201569 302201570 302201571 302201572 9 Pilot gas pipe Code Description MG 16T MG 24T MG 36T MG 48T MG 60T 1 Griddle plate 20129087001 20129088001 20129089001 ...

Page 10: ...9 302130019 302130019 302130019 5 gas valve 302220045 302220045 302220045 302220045 302220045 6 foot 302090047 302090047 302090047 302090047 302090047 7 burner assy 302130363 302130363 302130363 302130363 302130363 8 inlet gas pipe 302201568 302201569 302201570 302201571 302201572 9 Pilot gas pipe ...

Reviews: