Electrical Requirements
Please look at the rating label to know the rating voltage and
connect the dishwasher to the appropriate power supply. Use the
required fuse 10 amp, time delay fuse or circuit breaker recommended
and provide separate circuit servingonly this appliance.
Electrical Connection
Ensure the voltage and frequency of the power being corresponds
to those on the rating plate. Only insert the plug into an electrical
socket which is earthed properly. If the electrical socket to which
the appliance must be connected is not appropriate for the plug,
replace the socket, rather than using a adaptors or the like as they
could cause overheating and burns.
Cold Water Connection
Connect the cold water supply hose to a
threaded 3/4(inch) connector and make sure
that it is fastened tightly in place.
If the water pipes are new or have not been
used for an extended period of time, let the
water run to make sure that the water is clear.
Water Connection
Insure proper ground exists before use
WARNING!
Please close the hydrant after using.
This precaution is needed to avoid the risk of the water inlet to be
blocked and damage the appliance.
Drain hose Connection
Insert the drain hose into a drain pipe with a minimum diameter
of 40mm, or let it run into the sink, making sure to avoid bending
or crimping it. The top of the hose must be less than 1000mm.
How to Drain Excess Water From Hoses
If the sink is 1000 higher from the floor, the excess water in hoses
cannot be drained directly into the sink. It will be necessary to
drain excess water from hoses into a bowl or suitable container
that is held outside and lower than the sink.
Water Outlet
Connect the water drain hose. The drain hose must be correctly
fitted to avoid water leaks. Ensure that the water drain hose is not
kinked or squashed.
PLEASE HANG UP THE DRAIN HOSE EITHER WAY OF A, B.
Front
Counter
MAX 1000mm
40mm
NOTE
The top of the
hose must be less
than 1000mm.
Drain pipe
108
107
GB