S2Tech MRL100 Instruction Manual Download Page 4

MRL100 / 942 / 699Plus 

 A1- Instruction Manual

  

Digital load / weight measuring system 

S2Tech srl

  Via Imperia, 28  Milano – ITALY 

Tel: +39 02 8910142 Fax: + 39 02 89124848     

e-mail: 

[email protected]

  

www.s2tech.it 

 

Version : UK 2r7 dated 25/06/15 
Page: 4/4 

 

Notice: 

The information in this manual is subject to change without notice.S2Tech  shall  not be  liable  for  technical  or  editorial  errors  or  omissions  contained  herein,  nor  for  incidental  or  consequential damages  resulting  from  the  furnishing, performance,  or  use  of  this material.      This  manual contains information protected by 

copyright. No part of this manual may be photocopied, or reproduced in any form, or translated without prior written consent from S2Tech.  

 

Z:\Manuali\LM MRL100_942_699A1\Traduzioni Maggio 2015\LM MRL_942_699A1 V2r7 UK .docx 

 

DMODE = 1 

DMODE = 0 

 

 

 

 

Note

: 0 to 10V output signal is available for 699 Plus A1 electronics (code 00.03.010.0010). 

J) Analog output connection scheme for code 00.03.010.0010: 

 

Analog Signal A1 = from 0 to 10V 

AGND = analog signal GND 

NOTE: 

In order to obtain the best accuracy from the instrument’s analog output signal it is mandatory to connect 699Plus 
analog output to the Inverter’s input, considering its input characteristics: 
 
A) Inverter with 

floating

 

input

:  

2 wire connection 

 

E.g. Inverter 

 

699Pus A1 

Pin 11 

Analog Common

 

 

AGND 

GND 

Pin V2 

Analog Input

 

 

Analog Signal 

Analog Signal 

 
 
 
 
 

B) Inverter with 

differential input

:  

use 3 wires

 to connect the lift’s Inverter to 699Plus analog output, i.e.: 

1.

 

Connect JP11.1 and JP11.2 to 699Plus’s screw terminal analog output GND 

at the 699Plus's end

2.

 

Connect JP11.3 to Analog Output signal. 

 

E.g. Inverter 

 

699Pus A1 

JP11.1

 

0V

 

 

 

 

JP11.2 

AIN-

 

 

AGND 

GND 

JP11.3 

AIN+

 

 

Analog Signal 

Analog Signal 

 

WARNING:  POWER  SUPPLY  MINUS,  provided to  699Plus  instrument  is NOT  the  AGND  analog output 
ground.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Document history 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16/06/15 

Updated analog output connections 

699Bv1.25 

699V4r0 

SP,FM 

DD, CK 

10/06/15 

Updated DAST flowchart 

699Bv1.25 

699V4r0 

SP 

DD, CK 

01/06/15 

Revision for MRL100 and 699PlusE images 

699Bv1.00 

699V4r0 

S.Piardi 

D.Disanto 

07/04/15

 

Text revised 

– max load, inverter, DAC flow chart 

699Bv1.00 

699V1r0 

S.Piardi 

D.Disanto 

05/03/15

 

Text 

revised on Inverter’s connection 

699Bv1.00 

699V1r0 

S.Piardi 

D.Disanto 

19/02/15 

First issue 

699Bv1.00 

699V1r0 

S.Piardi 

D.Disanto 

Rev. 

Date 

Description 

Firmware 

Hardware 

Writer 

Check 

 

Summary of Contents for MRL100

Page 1: ...n elevator ropes 1 Apply C screws to A sensor like shown in picture 2 Position the MultiRope MRL100 sensor A close to the ropes parallel to the cabin roof and insert all ropes in the slot between the...

Page 2: ...al Relay 2 Normally Closed contact 12 Screw Terminal Relay 2 Common contact 13 Screw Terminal Relay 1 Normally Open contact 14 Screw Terminal Relay 1 Normally Closed contact 15 Screw Terminal Relay 1...

Page 3: ...ound 50 of lift s rated capacity or as near as possible to lift s capacity Measurement performed by the 699F unit will be shown in the same engineering unit used for HI value Kg Lbf N etc Measurement...

Page 4: ...s analog output signal it is mandatory to connect 699Plus analog output to the Inverter s input considering its input characteristics A Inverter with floating input 2 wire connection E g Inverter 699P...

Page 5: ...Applicare le viti C al sensore A come da figura 2 Posizionare il sensore MultiRopeMRL A vicino alle funi parallelo al tetto della cabina inserire tutte le funi nello spazio tra le viti senza sovrappor...

Page 6: ...e Relay 1 contatto Normalmente Chiuso 15 Terminale a vite Relay 1 contatto comune 16 Terminale a vite alimentazione al sensore 17 Terminale a vite alimentazione al sensore 18 Terminale a vite segnale...

Page 7: ...o visualizzate nella stessa risoluzione ed unit di misura usata per la memorizzazione di HI le unit ingegneristiche Kg Lbf N etc non sono mostrate 3 FSCA valore di pieno carico dell ascensore in Kg od...

Page 8: ...nalogica del 699Plus all ingresso dell inverter tenendo conto delle caratteristiche di quest ultimo A Inverter con ingresso flottante connessione a 2 fili E s Inverter 699Pus A1 Pin 11 Comune analogic...

Page 9: ...en 1 Die Schrauben C wie in der Abbildung angegeben am Sensor A anbringen 2 Den Sensor MultiRopeMRL A nahe an den Seilen parallel zum Kabinendach einf hren Alle Seile in den Zwischenraum zwischen den...

Page 10: ...Bezug auf gemeinsam 7 Terminal mit Schrauben Relais 3 Kontakt normaler Weise offen 8 Terminal mit Schrauben Relais 3 Kontakt normaler Weise geschlossen 9 Terminal mit Schrauben Relais 3 Kontakt gemei...

Page 11: ...ndet wird so nah wie m glich an der Volllast Die Messungen des digitalen Instruments 699F werden in der gleichen Aufl sung und Messeinheit angezeigt wie die f r das Speichern von HI verwendeten die te...

Page 12: ...der analoge Ausgang der 699Plus an den Eingang des Inverters angeschlossen werden wobei die Merkmale dieses letztgenannten zu ber cksichtigen sind A Inverter mit erdfreiem Eingang Anschluss mit 2 Dr...

Page 13: ...is C au capteur A selon la figure 2 Positionner le capteur MultiRopeMRL A pr s des c bles parall lement au toit de la cabine installer tous les c bles dans l espace entre les vis sans les superposer 3...

Page 14: ...alement ferm 9 Vis terminale Relais 3 contact commun 10 Vis terminale Relais 2 contact normalement ouvert 11 Vis terminale Relais 2 contact normalement ferm 12 Vis terminale Relais 2 contact commun 13...

Page 15: ...s la m me r solution et unit de mesure utilis es pour la m morisation d HI les unit s d ing nierie Kg Lbf N etc ne s affichent pas 3 FSCA valeur de charge pleine de l ascenseur en kg ou dans une autre...

Page 16: ...eur en tenant compte des caract ristiques de ce dernier A Inverseur avec entr e flottante connexion 2 fils E s Inverseur 699Pus A1 Pin 11 Analogique Commun AGND GND Pin V2 Entr e analogique Analog Sig...

Page 17: ...olocar el sensor MultiRope MRL A cerca de los cables paralelo al techo de la cabina introducir todos los cables en el espacio entre los tornillos sin superponerlos 3 Cuando los cables se encuentran en...

Page 18: ...a 6 Terminal de tornillo Entrada salida referencia com n 7 Terminal de tornillo Rel 3 contacto Normalmente Abierto 8 Terminal de tornillo Rel 3 contacto Normalmente Cerrado 9 Terminal de tornillo Rel...

Page 19: ...nstrumento digital 699F se visualizan en la misma resoluci n y unidad de medida para la memorizaci n de HI no se muestran las unidades de ingenier a Kg Lbf N etc 3 FSCA valor de plena carga del ascens...

Page 20: ...ter teniendo en cuenta las caracter sticas de ste ltimo A Inverter con entrada flotante conexi n de 2 cables Ej Inverter 699Pus A1 Pin 11 Com n anal gico AGND GND Pin V2 Input Anal gico Analog Signal...

Page 21: ...nuali LM MRL100_942_699A1 Traduzioni Maggio 2015 LM MRL_942_699A1 V2r7 RU docx A Multirope MRL100 2 8 8 8 DIN 933 ISO 4762 M8 A2 C 1 MultiRope MRL 1 B A C F 3 6 6 5 F 4 6 6 5 F 6 6 6 5 B A MRL100 72 B...

Page 22: ...6 LIFTSENTRY 15 CE EN 61326 1 1997 A1 1998 A2 2001 A3 2003 EN 61000 6 2 2001 EN 61000 3 2 2000 A2 2005 EN 61000 3 3 1995 A1 2001 EN 61000 4 2 1995 A1 1998 A2 2001 EN 61000 4 3 2002 A1 2002 EN 61000 4...

Page 23: ...L_942_699A1 V2r7 RU docx F 699 MANU 0 MultiRope 699 C RESET C MANU E 699 MEMO C E 10 100 C 10 100 C SAVE 699Plus 1 TARE 0 TARE E 60 T 60 T 0 MEMO TARE 2 HI E 60 T 60 T 0 HI MEMO HI 50 100 699F HI 3 FS...

Page 24: ...x DMOD DMODE 1 DMODE 0 0 10 699Plus A1 00 03 010 0010 J 00 03 010 0010 A1 0 10 AGND 699Plus A 2 699Pus A1 11 AGND GND V2 B 3 699Plus 1 JP11 1 JP11 2 AGND 699Plus 2 JP11 3 699Pus A1 JP11 1 0V JP11 2 AI...

Reviews: