background image

S2Konnect S-8180T

11

Connection to other Switches

The S2Konnect Unmanaged Switch can be connected directly to the port of another switch (or 

hub) as each port of the S2Konnect Unmanaged Switch supports Auto MDI and MDIX functiona-

lities. 

In order to connect two Switches with one another, proceed as follows:

1. 

If possible, disconnect the Switches from the power supply.

2. 

At one end of the cable connect the RJ-45 connector to the port on the S2Konnect

 

Unmanaged Switch (see figure 4).

3. 

At the other end of the cable connect the connector to the port of the other switch. The  

 

port type (e.g. 1000Base-T) of both Switches must be identical.

4. 

Reconnect both Switches to the power supply.

5. 

Turn on the Switches.

6. 

At the S2Konnect Unmanaged Switch check the SPD/LNK/ACT LED belonging to the  

 

port you plugged in the plug to find out if the cable is connected correctly.

 

If the LED is on, the connection is established and active. Otherwise you have to check  

 

the S2Konnect Unmanaged Switch more closely (for details, refer to section

 

“LED Displays” on page 13).

 

If possible, check the LED on the other switch in the same manner.

 

If the LED should not light up, refer to the appropriate switch manual to find the error.

Keep attention to use only one cable to connect two Switches. The use of multiple cables can 

create a loop and cause collisions.

Figure 4. Connection Switches

!

Summary of Contents for S-8180T

Page 1: ......

Page 2: ...S2Konnect S 8180T S2Konnect S 8180T Unmanaged Gigabit Ethernet Switch User Manual 2...

Page 3: ...2Konnect S 8180T Unmanaged Switches Contents are subject to change without notice Product and brand names are registered trademarks of their appropriate owners If you have comments on this documentati...

Page 4: ...te a potentially hazardous situation which if not avoided could result in death or serious injury Example dangerous voltage Used to indicate a potentially hazardous situation which if not avoided may...

Page 5: ...naged Switch 10 Transmission Distances 10 Connection to the Network 10 Connection to other Switches 11 3 Features 12 Type of Switch 12 Front Panel 12 Rear Panel 13 RJ 45 Switch Ports 13 SFP Port 13 LE...

Page 6: ...Wall Installation Figure 2 Rack Installation Figure 3 Connection of the RJ 45 cable plug Figure 4 Connection of Switches Figure 5 Front Panel of the S 8180T Figure 6 Rear Panel of the S2Konnect Unmana...

Page 7: ...ing of the products using the cord does not exceed the extension cord s ampere rating Do not attempt to service this device as opening or removing casing may expose you to dangerous voltage points or...

Page 8: ...of weight Installation on a Wall To install the S2Konnect Unmanaged Switch on the wall proceed as follows 1 Attach the brackets at each side of the S2Konnect Unmanaged Switch using the supplied screw...

Page 9: ...S2Konnect Unmanaged Switch using the supplied screws 2 Insert cage nuts into the mounting rail of the rack 3 Hold the S2Konnect Unmanaged Switch against the rack ensuring that the bracket holes align...

Page 10: ...h to a network proceed as follows 1 If possible disconnect the S2Konnect Unmanaged Switch from the power supply 2 At one end of the cable connect the RJ 45 connector to the port on the S2Konnect Unman...

Page 11: ...type e g 1000Base T of both Switches must be identical 4 Reconnect both Switches to the power supply 5 Turn on the Switches 6 At the S2Konnect Unmanaged Switch check the SPD LNK ACT LED belonging to t...

Page 12: ...the power LED link and status LEDs and RJ 45 ports All 8 ports with RJ 45 connectors can negotiate full and half duplex modes automatically They may be connected to 10Base T 100Base T and 1000Base T...

Page 13: ...ite Please go to www s2konnect com support section You will also find the procedure for returning a switch for repair on that section S2Konnect cannot accept any returned product without an RMA number...

Page 14: ...1000Base T IEEE 802 3x mit Flow control Auto negotiation IEEE 802 1p Quality of Service IEEE 802 3ab Gigabit Ethernet standards Safety Standards CSA CB CE UL EMC CE Class A FCC Class B Environmental...

Page 15: ...nty 2 Years Order numbers 100 001 001 008 Copyright 2009 S2Konnect All rights reserved All brand and product names are trademarks or registered trademarks of their respective holders Specifications ar...

Page 16: ...ility for specific applications or customer network environments Limited Warranty for Hardware and Software Limited Warranty S2Konnect warrants that the SOFTWARE will perform substantially in accordan...

Page 17: ...e accompanying Product Manual s for a period of 90 days from the date of receipt if you have created the required technical preconditions S2Konnect warrants that NETWORK INTERFACE CARDS will be free f...

Page 18: ...Person die Software auch auf einem tragbaren Computer oder einem Heimcomputer benutzen Urheberrecht Die Software ist Eigentum von S2Konnect oder deren Lieferanten und ist durch Urheberrechtsgesetze in...

Reviews: