Connecting scheme 

Parallel operation

Connecting scheme 

Individual operation

SUPPLY VOLTAGE :

For operating voltage reverse polarity protection, a one-way rectifier or 
reverse polarity protection diode is integrated in this device variant. 

 

This internal one-way rectifier also allows operating 0 - 10 V devices on AC 
supply voltage.

The output signal is to be tapped by a measuring instrument. Output 
 voltage is measured her against zero potential (O V) of the input voltage!

When this device is operated on 

DC supply voltage

,  the operating voltage 

input UB+ is to be used for 15...36 V DC supply and UB – or GND for ground 
wire!

When several devices are supplied by one 24 V

 AC voltage supply

, it is to 

be ensured that all ”positive“ operating voltage input terminals (+) of the 
field devices are connected with each other and all ”negative“ operating 
voltage input terminals (–) (= reference  potential) are connected together 
(in-phase connection of field devices). All outputs of field devices must be 
referenced to the same potential!

In case of reversed polarity at one field device, a supply voltage short- 
circuit would be caused by that device. The consequential short-circuit 
current flowing through this field device may cause damage to it.

Therefore, pay attention to correct wiring!

Circuitry

Circuitry

0...10V

0V/GND

0...10V

0V/GND

Power supply

AC 24V~ 

0V

DC 15-36V =  GND

Circuitry

0...10V

0V/GND

V

Power supply

AC 24V~ 

0V

DC 15-36V =  GND

G  

Measuring transducers, calibrateable, with active output  

Load resistance diagram 

4 … 20 mA 

Dependency of output voltage on output current

Output: 

 ...........................

4...20 mA

Connection: ......................2-wire connection
Auxiliary energy:  ..............15 ... 36 V  DC    ± 10  %,   

supplied from 4...20 mA loop, 

residual ripple, stabilised   ≤  ± 0.3  V

Working resistance:..........Ra (Ohm) = (Ub-14 V)  ⁄  0.02 A

Output: 

 ...........................

0 - 10 V

Connection: ......................3-wire connection
Auxiliary energy:  ..............24 V  AC  ⁄  DC    ±  20  %
Working resistance:..........minimum load resistance 5 kOhm

Accuracy: ........................± 0.4 K at 25 °C, otherwise ± 0.8 K
Measuring element: ..........see table
Operating temperature: ....transmitter  – 30...+ 70 °C
Linearisation: ...................temperature linear  

according to DIN IEC 751

Linearity error: ................± 0.3 %  of measuring range 
Standards: .......................CE conformity, electromagnetic compatibility  

according to EN 61326: 2006, 

according to EMC directive 2004 ⁄ 108 ⁄ EC

TEMPERATURE RANGES:

When selecting measuring transducer ranges,  
it is necessary to ensure that the maximum temperatures  
permissible for sensor  ⁄ enclosure are not exceeded !

Ambient temperature for measuring transducers:  
– 30 ...+ 70 °C

Apparent ohmic resistance  =  see load resistance diagram

Ia

 (mA)

12

10

8

6

4

2

0

0

1.5

0.5

2.5

3.5

4.5

1.0

2.0

3.0

4.0

Ua

  (V)

800

700

600

500

400

300
250

50

200

10

15

20

25

30 35 36 40

Load resistance diagram

W

orking r

esis

tanc

e  (Ohm)

Operating voltage  (V DC)

Admissible

  range

6

7

8

# 14 -4020   (wie Katalog-

2014

, ab Seite 034)

ENDFASSUNG

  |  29. 01. 2014  ⁄ PR

  

 

# 223

00 - 2014

Summary of Contents for THERMASGARD HFTM Series

Page 1: ...g Instructions Mounting Installation Sleeve sensors with temperature measuring transducer calibrateable with multi range switching and active output F Notice d instruction Sonde chemis e avec converti...

Page 2: ...THERMASGARD HFTM D G F r Ma zeichnung HFTM Dimensional drawing Plan cot 50 KL 6 107 72 M12x1 5 64 14 8 43 3 M16x1 5 2 14 4020 wie Katalog 2014 ab Seite 034 ENDFASSUNG 29 01 2014 PR 22300 2014...

Page 3: ...A 24 V DC 2 2 VA 24 V AC Sensor Pt1000 DIN EN 60751 Klasse B Messbereiche Mehrbereichsumschaltung mit 8 umschaltbaren Messbereichen siehe Tabelle andere Messbereiche optional mit manueller Nullpunktko...

Page 4: ...s Ger tes f hren Achten Sie daher auf die korrekte Verdrahtung Schaltung Schaltung 0 10V 0V GND 0 10V 0V GND Versorgung mit AC 24V 0V DC 15 36V GND AC 24V 0V DC 15 36V GND Schaltung 0 10V 0V GND V Ver...

Page 5: ...ellung sind nicht zus tzlich aufgef hrt und im Sinne des technischen Fortschritts und der stetigen Verbesserung unserer Produkte m glich Bei Ver nderungen der Ger te durch den Anwender entfallen alle...

Page 6: ...nsor Pt1000 DIN EN 60751 class B Measuring ranges multi range switching with 8 switchable measuring ranges see table other ranges optional with manual zero point correction 10K Output 0 10 V or 4 20 m...

Page 7: ...Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND G Measuring transducers calibrateable with active output Load res...

Page 8: ...hese devices shall only be used for their intended purpose Respective safety regulations issued by the VDE the states their control authori ties the T V and the local energy supply company must be obs...

Page 9: ...jusqu 250 C ou soie de verre avec tresse inox jusqu 350 C Bo tier mati re plastique polyamide renforc 30 de billes de verre avec vis de fermeture rapide association fente fente en croix couleur blanc...

Page 10: ...Veillez donc au raccordement correct des fils Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND F Convert...

Page 11: ...du T V et des entreprises d approvisionnement en nergie locales sont respecter L acheteur doit respecter les dispositions relatives la construction et la s curit et doit viter toutes sortes de risques...

Page 12: ...64 x 43 3 Thor III M 16 x 1 5 10 4 0 14 1 5 95 III EN 60 730 IP65 EN 60529 IP68 CE EN 61 326 2006 2004 108 EC 36 x 15 x 1 HFTM 1 I IP65 I HFTM I Pt1000 4 20 A 1101 1152 0219 920 HFTM I_DISPLAY Pt1000...

Page 13: ...B Ra Ub 14 B 0 02 A Ub 0 10 B 24 B 20 5 0 4 K 25 C 0 8 K 30 70 C DIN IEC 751 0 3 CE EN 61 326 2006 2004 108 EC 30 70 C c Ia A 12 10 8 6 4 2 0 0 1 5 0 5 2 5 3 5 4 5 1 0 2 0 3 0 4 0 Ua B 800 700 600 500...

Page 14: ...r EMV ZBEI VDE VDI DDC PLC 0 5 g 0 10 0 10 4 20mA 4 20 4 VDE r ZVEI VDE EMV 14 14 4020 wie Katalog 2014 ab Seite 034 ENDFASSUNG 29 01 2014 PR 22300 2014...

Page 15: ...ires Copyright by S S Regeltechnik GmbH Nachdruck auch auszugsweise nur mit Genehmigung von S S Regeltechnik GmbH gestattet Reprints in part or in total are only permitted with the approval of S S Reg...

Page 16: ...3 fils pour appareils cran r tro clair 12 3 1 2 4 5 3 ON passiver Sensor passiver Sensor UB 24 V DC Ausgang 4 20 mA in C UB GND Hintergrund beleuchtung interner Sensor passiver Sensor DIP Schalter Mes...

Reviews: