![S+S Regeltechnik RYM7-10IB-2102-000 Operating Instructions Manual Download Page 4](http://html1.mh-extra.com/html/s-s-regeltechnik/rym7-10ib-2102-000/rym7-10ib-2102-000_operating-instructions-manual_793924004.webp)
S+S REGELTECHNIK GMBH | THURN-UND-TA XIS-STR. 22 | D-90411 NÜRNBERG | GERMANY | FON +49 (0) 911 51947- 0 | w w w.S plusS.de
4
Operating instructions
RYM
ASKON
®
700 - BACnet
RYM
ASKON
®
700 - Modbus
PC/Laptop
System
USB
RYMASKON
USB CT
RYMASKON
500/600/700
KEY FEATURES
Basic model type 710
• 24 V AC/DC voltage supply
• 3.5 inch touch display with backlighting
• Modbus or BACnet
• Wall mounting on standard in-wall flush boxes
• Integrated temperature sensor (basic equipment)
• Integrated humidity sensor
• Integrated CO2 sensor (optional)
• Regulation of heating, cooling, fans
via the bus
• Operation of temperature,
fan, light, A ⁄ C (air conditioning) (1 zone)
and sun protection (2 zones)
via touch display
• 2 resistance inputs (NTC10K)
for external temperature sensors
• 1 relay output (7A / 0.5A with CO2)
as 2-point regulator (potential-free)
controllable via bus
• 1 digital input (potential-free)
• Operating modes Comfort (Normal),
OFF, Party (Boost), ECO, Frost Protection
RYMASKON USB-CT
Configuration tool
for rapid transfer of the
unit configuration
A configuration can be transferred to other units.
To do so, a unit must first be configured using the display via the bus.
After which the
RYMASKON USB-CT
and software on the PC can be used to transfer the configuration to other units.
The current software and detailed information are available in the
RYMASKON USB-CT
download area (spluss.de/r/2L6VM.htm).
Connection plan of the configuration tool
4