D

  

Bedienungs- und Montageanleitung

Vitrinen-Feuchte- und Temperaturfühler (± 2,0 %),  
kalibrierfähig, mit Mehrbereichsumschaltung  
und aktivem Ausgang

G

  

Operating Instructions, Mounting & Installation

Showcase humidity and temperature sensors (± 2.0 %),  
calibratable, with multi-range switching  
and active output

F

  

Notice d’instruction

Sonde d'humidité et de température pour vitrines (± 2,0 %),  
étalonnable, avec commutation multi-gamme  
et sortie active

r

  

Руководство по монтажу и обслуживанию

Витринный датчик влажности и температуры (±2,0 %),  
калибруемый, с переключением между несколькими  
диапазонами и активным выходом

S+S REGELTECHNIK GMBH 
PIRNAER STRASSE 20 
90411 NÜRNBERG ⁄ GERMANY

FON  +49 (0) 911 ⁄ 5 19  47- 0 
FAX  +49 (0) 911 ⁄ 5 19  47- 70

[email protected] 
www.SplusS.de

6000-2690-0000-2XX   

26900-2018  V200

    02  ⁄  2018

Summary of Contents for HYGRASGARD VFF-I

Page 1: ...ierf hig mit Mehrbereichsumschaltung und aktivem Ausgang G Operating Instructions Mounting Installation Showcase humidity and temperature sensors 2 0 calibratable with multi range switching and active...

Page 2: ...isplay without display sans cran mit Display with display avec cran 11 0 5 2 5 M16x1 5 M16x1 5 M12x1 5 64 14 8 43 3 M12x1 5 M10x1 0 64 14 8 37 8 Stecker Plug Sonde Probe 25 25 10 14 17 KL 107 72 39 49...

Page 3: ...chte 0 100 r H Ausgang entspricht 0 10 V oder 4 20 mA Arbeitsbereich Feuchte 0 95 r H ohne Betauung Abweichung Feuchte typisch 2 0 20 80 r H bei 25 C sonst 3 0 Ausgang Feuchte 0 10 V bei U Variante 4...

Page 4: ...Ger tevariante eine Einweggleichrichtung bzw Verpolungschutzdiode integriert Diese interne Einweggleichrichtung erlaubt auch den Betrieb mit AC Versorgungs spannung bei 0 10 V Ger ten Das Ausgangssign...

Page 5: ...chen EVU zu beachten Der K ufer hat die Einhaltung der Bau und Sicherungsbestimmung zu gew hrleisten und Gef hrdungen aller Art zu vermeiden F r M ngel und Sch den die durch unsachgem e Verwendung die...

Page 6: ...nge humidity 0 95 r H without formation of dew Deviation in humidity typically 2 0 20 80 r H at 25 C otherwise 3 0 Output humidity 0 10 V for U variant 4 20 mA for I variant see load resistance diagra...

Page 7: ...rcuit would be caused by that device The consequential short circuit current flowing through this field device may cause damage to it Therefore pay attention to correct wiring Circuitry Circuitry 0 10...

Page 8: ...supply company must be observed The purchaser has to adhere to the building and safety regulations and has to prevent perils of any kind No warranties or liabilities will be assumed for defects and da...

Page 9: ...de mesure humidit 0 100 h r sortie correspond 0 10 V ou 4 20 mA Plage de service humidit 0 95 h r sans condensation Incertitude de mesure humidit typique 2 0 20 80 h r 25 C sinon 3 0 Sortie humidit 0...

Page 10: ...tension d alimentation sur un des appareils de terrain provoquerait un court circuit Le courant de court circuit passant par cet appareil de terrain peut endommager cet appareil Veillez donc au raccor...

Page 11: ...surveillance du T V et des entreprises d approvisionnement en nergie locales L acheteur doit respecter les dispositions relatives la construction et la s curit et doit viter toutes sortes de risques...

Page 12: ...20 0 95 2 0 20 80 25 C 3 0 0 10 B U 4 20 I 4 35 35 C 35 75 C 0 50 C 0 80 C 0 10 B 4 20 0 2 K 25 C 0 10 4 20 5 60 C 5 60 C 1 30 RAL 9016 72 x 64 x 37 8 Tyr 1 72 x 64 x 43 3 Tyr 1 M 16 x 1 5 10 4 0 14 1...

Page 13: ...0 25 30 35 36 40 Load resistance diagram Working resistance Ohm Operating voltage V DC Admissible range 800 700 600 500 400 300 250 50 200 10 15 20 25 30 35 36 4 Load resistance diagram Working resist...

Page 14: ...SPLAY 0 100 4 20 A 1201 6122 0200 100 VFF U 0 100 0 10 1201 6121 0000 100 VFF U DISPLAY 0 100 0 10 1201 6121 0200 100 VFTF VFTF I 0 100 35 75 C 35 35 C 0 50 C 0 80 C 4 20 A 4 20 A 1201 6122 1000 100 V...

Page 15: ...AC DC Schematic diagram Sch ma de raccordement 1 2 3 4 5 6 1 2 0N Offset C r H Plug display DIP switches multi range switching UB 24V AC DC Output humidity 0 10V in r H Output temperature 0 10V in C U...

Page 16: ...5 K Humidity 10 r H 1 2 3 4 5 6 1 2 0N Offset C r H UB 24V DC Ausgang Feuchte 4 20mA in r H Ausgang Temperatur 4 20mA in C UB GND optional f r LCD Hintergrundbeleuchtung Stecker Display passiver Senso...