Devices are to be connected under dead-voltage condition. Devices must 
only be connected to safety extra-low voltage. Consequential  damages 
caused by a fault in this device are excluded from warranty or liability. 
Installation of these devices must only be realized by authorized qualified 
personnel. The technical data and connecting conditions shown on the 
device labels and in the mounting and operating instructions delivered 
 together with the device are exclusively valid. Deviations from the cata-
logue representation are not explicitly mentioned and are possible in 
terms of technical progress and continuous improvement of our pro-
ducts. In case of any modifications made by the user, all warranty claims 
are  forfeited. Operating this device close to other devices that do not 
comply with EMC directives may influence functionality. This device must 
not be used for monitoring applications, which solely serve the purpose 
of protecting persons against hazards or injury, or as an EMERGENCY 
STOP switch for systems or machinery, or for any other similar safety-
relevant purposes.
Dimensions of enclosures or enclosure accessories may show slight 
tolerances on the specifications provided in these instructions. 
Modifications of these records are not permitted. 
In case of a complaint, only complete devices returned in original pack-
ing will be accepted.
Our “General Terms and Conditions for Business“ together with the 
“General Conditions for the Supply of Products and Services of the 
Electrical and Electronics Industry“ (ZVEI conditions) including supple-
mentary clause “Extended Retention of Title“ apply as the exclusive 
terms and conditions“.

Notes regarding mechanical mounting and attachment:
Mounting shall take place while observing all relevant regulations and 
standards applicable for the place of measurement (e.g. such as welding 
instructions, etc.). Particularly the following shall be regarded:
– VDE  ⁄  VDI directive technical temperature measurements, measure-

ment set - up for temperature measurements.

– The EMC directives must be adhered to. 
– It is imperative to avoid parallel laying of current-carrying lines.
– We recommend to use shielded cables with the shielding being 

 attached at one side to the DDC  ⁄  PLC.

Before mounting, make sure that the existing thermometer‘s technical 
parameters comply with the actual conditions at the place of  utilization, 
in particular in respect of:
– Measuring range 
– Permissible maximum pressure, flow velocity 
– Oscillations, vibrations, shocks are to be avoided (< 0.5 g)

CONNECTING CONDITIONS

Output:   0  - 10  V
The output voltage follows linear to the temperature signal applied at  
the input terminals and generates a proportional output signal of 0 - 10 V. 
The voltage outputs are short-circuit proof against ground wire. Applying 
voltage supply to the output terminals will destroy the device.

Output:   4 ... 20 mA
In case of the 4 ... 20 mA measuring transducer, display and evaluating 
 elements are connected in series in the current loop. The measuring 
transducer thereby liWiths the flowing current in variance of the input 
signal. 4 mA are for the measuring transducer‘s internal current con-
sumption. The apparent ohmic resistance can either be connected in the 
plus or minus path of the measuring transducer. In case of an apparent 
ohmic resistance in the plus path, power supply and resist.

SAFETY REGULATIONS
These devices shall only be used for their intended purpose. Respective 
safety regulations issued by the VDE, the states, their control authori-
ties, the TÜV and the local energy supply company must be observed. The 
buyer has to ensure adherence to the building and safety regulations and 
has to avoid all dangers of any kind. We do not assume any warranty for 
faults or damages arising or resulting from improper use of our equip-
ment or from non-observance of operating instructions. These instru-
ments must be installed by authorised specialists only!

Preferably shielded cables should be used in order to prevent damages  ⁄  
errors. It is imperative to avoid laying parallel with current-carrying 
lines. EMC directives must be adhered to.

G  

Mounting and Installation

Mounting diagram 

MWTM

8

Summary of Contents for 1101-3131-0089-900

Page 1: ...sumschaltung und aktivem Ausgang G Operating Instructions Mounting Installation Mean value temperature measuring transducers including mounting flange calibrateable with multi range switching and acti...

Page 2: ...rawing Plan cot MWTM 107 64 14 8 37 8 M16x1 5 72 56 8 22 5 5 3 6 2 4 2 24 4 6 KL 60 60 84 3 NL MWTM mit Schnellverschlussschrauben with quick locking screws avec vis de fermeture rapide MWTM mit Dipla...

Page 3: ...utenwerkstoff F hlerrohr aus Kupfer mit Kunststoff berzug mit Knickschutzfeder F hler und Rutenabmessungen 5 0 mm Nennl nge NL 0 4 m 3 m 6 m Nennl nge optional bis max 20 m aktive L nge auf der gesamt...

Page 4: ...hlussstrom kann zur Besch digung dieses Ger tes f hren Achten Sie daher auf die korrekte Verdrahtung Schaltung Schaltung 0 10V 0V GND 0 10V 0V GND Versorgung mit AC 24V 0V DC 15 36V GND AC 24V 0V DC 1...

Page 5: ...Temperaturmessungen Richtlinie Mess an ord nungen f r Temperaturmessungen die EMV Richtlinien diese sind einzuhalten eine Parallelverlegung mit stromf hrenden Leitungen ist unbedingt zu vermeiden es...

Page 6: ...d material copper sensor tube plastic coated with spring for buckling protection Sensor and rod dimensions 5 mm nominal length NL 0 4 m 3 m 6 m NL optional up to 20 m Active length active over the ent...

Page 7: ...attention to correct wiring Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND G Measuring transducers cal...

Page 8: ...ts measure ment set up for temperature measurements The EMC directives must be adhered to It is imperative to avoid parallel laying of current carrying lines We recommend to use shielded cables with t...

Page 9: ...Mat riau c ble de mesure tube de sonde en cuivre rev tu d un gainage plastique avec ressort anti cassure Dimensions de la sonde et du capillaire 5 0 mm longueur nominale NL 0 4 m 3 m ou 6 m longueur...

Page 10: ...e terrain peut endommager cet appareil Veillez donc au raccordement correct des fils Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power s...

Page 11: ...mp ratures selon VDE VDI directives ordon nances sur les instruments de mesure pour la mesure de temp ratures Les directives CEM celles ci sont respecter Ne pas poser les c bles de sonde en parall le...

Page 12: ...35 G K 05 95 III EN 60 730 IP 65 EN 60 529 CE EN 61 326 2006 2004 108 EC 36 x 15 x r THERMASGARD MWTM 1 MWTM I NL IP65 I MWTM I 0 4M Pt1000 4 20 A 0 4 1101 3132 0089 900 MWTM I 3M Pt1000 4 20 A 3 0 11...

Page 13: ...ND r 4 20 A 4 20 A 15 36 B 10 4 20 0 3 B Ra Ub 14 B 0 02 A Ub 0 10 B 24 B 20 5 0 4 K 25 C 0 8 K 30 70 C DIN IEC 751 0 3 CE EN 61 326 2006 2004 108 EC 30 70 C c Ia A 12 10 8 6 4 2 0 0 1 5 0 5 2 5 3 5 4...

Page 14: ...EMV ZBEI VDE VDI DDC PLC 0 5 g 0 10 0 10 4 20mA 4 20 4 VDE r MWTM...

Page 15: ...MK 05 M Dimensional drawing Plan cot MK 05 M KRD 04 Ma zeichnung KRD 04 Dimensional drawing Plan cot Copyright by S S Regeltechnik GmbH Nachdruck auch auszugsweise nur mit Genehmigung von S S Regelte...

Page 16: ...hes Measuring range changeover Contact pin side Display connector max min 10K Offset 12 3 1 2 4 5 3 ON Passive sensor Passive sensor UB 24 V AC DC Output 0 10 V in C UB GND Internal sensor Passive sen...

Reviews: