For Effective Cooling

Close the windows and pull down blinds. Sunshine is reduced and cooling efficiency increases.
Paste heat shield film on the window. Heat entering the room is reduced.
Block the outdoor unit from direct sunlight. This saves energy.

Maintenance While in Use

The unit should be cleaned regularly
Turn off the power supply before cleaning
Clean the indoor unit using a soft cloth. If the unit is very dirty use a solution of detergent in lukewarm

Clean the air filter regularly (Refer to the section of  leaning the air Filter )
If the outdoor unit is installed on the roof, Clean the surroundings around the outdoor unit regularly to

 prevent dirt or rubbish from blocking the heat exchanger. 

When the Air Conditioner is not going to be used for a long time 

Perform FAN operation for 3-4 hours to dry the inside of the air conditioner.
Remove the batteries from the remote control
Disconnect the power plug or switch off at the mains power.

Preparation and maintenance when the air conditioner is to be used again

Clean the air filter and install ir in the indoor unit. 
Connect the power plug or switch on at the mains power
Check that the air inlet and outlet of the indoor/outdoor units are not blocked.

CAUTION

Do not operate the air conditioner without the air filter installed.
Do not use gasoline benzene, polish powder, detergent or hot water more than 40

Operation and Maintenance

Efficient Operation 

In order to increase the efficiency of the operation and considering your health we recommend you use
the unit as follows. 

If the air conditioner cannot be operated ensure: 

1. The power plug is connected. The switch is turned on and the fuse is not blown
2. The leakage breaker is not turned off
3. The power source is current 

Before Contacting the Serviceman 

4. The air conditioner keeps stoping during operation. Test the power by pressing the ON/OFF button again
5. The ON timer is not set. 

The air conditioner does not cool or heat sufficiently. Check

1. The temperature setting is correct. The set temperature should be lower than the room temperature in 

COOL mode. While in heat mode the set temperature should be higher than room temperature.

2. If a door is open or there are too many people in a room or other electronic appliances are generating

 heat from operating. 

3. Outlet and inlets of the outdoor unit are not blocked
4. Air filter is not dirty.

Display on remote control does not appear or the remote control signal cannot be received. Check

1. The batteries are exhausted
2. The polarity (+) (-) of the batteries is confused.

CAUTION

During a thunderstorm stop operation and pull out the power plug or turn off the mains switch as damage

maybe caused to the electrical parts. 
In a weak radio wave area when the air conditioner is operated it may cause noise in SW radio reception.
The remote control signal may not be received in a room where an electronic type fluorescent lamp is used.

If the above items are checked and the air condition does not recover stop using and contact the service 

dealer or the manufacturer advising the producttype and the failure details.  

water then clean it again using a soft damp cloth.  

10| 

Page

11 | 

Page

Summary of Contents for TKF-26GW/BP

Page 1: ...P 9000BTU TKF R 35GW BP 12000BTU TKF R 50GW BP 18000BTU TKF R 70GW BP 24000BTU TKF R 100GW BP 36000BTU TKF R 120GW BP 41000BTU TKF R 140GW BP 48000BTU SOLAR AIR CONDITIONER OPERATION AND INSTALLATION...

Page 2: ...ting Page 18 Draining Piping Work Page 18 Sealing of the Wall Hole Fixing of the Piping Page 19 Electric Wiring Connection Trial Operation Page 20 Electric Wiring Connection Page 20 Trial Operation Pa...

Page 3: ......

Page 4: ...ration 1 Press the ON OFF button to stop the air conditioner 1 Press the ON OFFbutton to start the air conditioner 2 To select AUTO mode press the Operation select button Each time the button is press...

Page 5: ...he TIMER ON button and the will flash on the screen 3 When the icon flashes the start timer can be set Press the HOUR and Minute buttons to adjust the required time 4 Once the start time has been set...

Page 6: ...considering yourhealth we recommend you use the unit as follows If the air conditioner cannot be operated ensure 1 The power plug is connected The switch is turned on and the fuse is not blown 2 The l...

Page 7: ...humidity etc Cleaning of the Air Filter and Deodorising Filter Cleaning the air filter every 2 weeks 1 Open the front panel to the position as shown and remove the air filter The position of the fron...

Page 8: ...his is the sound of refrigerant flowing inside the air conditioner 8 Mist appears during COOL operation The indoor warm air is cooled when the room temperature and the humidity is high When the room t...

Page 9: ...UT 9 52 3 8 12 7 1 2 6 35 1 4 22000 24000 BUT 9 52 3 8 15 88 5 8 9 52 3 8 Pipe Diameter inch Tightening Torque kgf cm 1 4 220 280 3 8 350 420 1 2 530 590 5 8 750 800 3 Refrigerant and drainage piping...

Page 10: ...rts to increase rapidly stop temporarily then turn through 60 90 angle If the pipe length is more than 3m charge the system with additional refrigerant Draining Piping Work In order to confirm that th...

Page 11: ...ightly Trial operation Before trial operation be sure to check for looseness in wiring and mistaken polarity etc 1 Connect the power plug then turn on the mains switch Observe if the operation indicat...

Reviews: