2.  A minimum clearance area in front of the slide shall be maintained at all times as 
follows:  
 
The minimum clearance distance on either side of 
the extended centerline of the slide runway shall not 
be less than three feet six inches (3’-6”) at a point 
no less than two feet six inches (2’-6”) from the exit 
lip of the slide and extending a distance of thirteen 
feet six inches (13’-6”) in front of the slide as shown 
in FIGURE 3. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3.  SLIDE PLACEMENT INSTRUCTIONS FOR INSTALLATIONS ON POOLS WITH 

OTHER SLIDES AND/OR DIVING BOARDS  

 

A.  The minimum clearance area in front of a properly installed diving board on an 

inground swimming pool is a minimum distance of three feet six inches (3’-6”) on 
either side of the board’s centerline as shown in FIGURE 4.  Pt. C extends a 
minimum distance of “C” from the tip end of the board as shown in FIGURE 4.  
The width distance “W” on either side of Pt. C is given in CHART 1 and shown in 
FIGURE 4. 

FIGURE 3

Summary of Contents for rogue2

Page 1: ...R SMITH LLC 2006 OCT13 CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P O Box 400 1017 SW Berg Parkway Canby Oregon 97013 Phone 503 266 2231 Fax 503 266 4334 www srsmith com SLIDE OWNER...

Page 2: ...ED USE INSTRUCTIONS 4 INSTALLED ROGUE2 STRUCTURAL INSTALLATION CHECKLIST 5 DAILY WEEKLY MAINTENANCE OF THE ROGUE2 5 APPLICABLE STANDARDS AND CODES 5 ASSEMBLY AND INSTALLATION 5 DRAWINGS 6 SUBSEQUENT O...

Page 3: ...CHIEF DANGER OF HEAD FIRST SLIDING IS SERIOUS SPINAL INJURY INJURIES TO THE SPINE MAY RESULT IN TEMPORARY OR PERMANENT PARALYSIS OR EVEN DEATH RESEARCH STUDIES HAVE SHOWN THAT YOU CANNOT RELY ON THE...

Page 4: ...TIL ALL SUBMERGED OBSTACLES SURFACE OBJECTS OR OTHER SWIMMERS ARE CLEAR OF THE SLIDER S PATHWAY 8 DO NOT USE THE SLIDE WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS 9 DON T SLIDE ALONE USE THE BUDDY S...

Page 5: ...way any dust dirt or other debris which may have accumulated 2 Be sure that all connections are secure Tighten hardware if necessary 3 All polyethylene parts require little maintenance Hose and wipe t...

Page 6: ...nsions for placement of the Rogue2 slide are as shown in Figures 2 and 3 A The slide exit runway surface shall not exceed twenty inches 20 above the water surface as shown in Figure 2 B The slide shal...

Page 7: ...six inches 13 6 in front of the slide as shown in FIGURE 3 3 SLIDE PLACEMENT INSTRUCTIONS FOR INSTALLATIONS ON POOLS WITH OTHER SLIDES AND OR DIVING BOARDS A The minimum clearance area in front of a...

Page 8: ...water when possible In addition you may safely use the below listed products Always try a test spot before applying to a large area Windex With Ammonia Formula 409 Fantastik Soft Scrub Scrubfree Tackl...

Page 9: ...Lysol Disinfectant Ajax Cleanser Windex With Vinegar White Cap Ajax Liquid Serious Equipment Serious Fun Product Name Rogue2 Serial Number ___________________ located on label attached to slide Purcha...

Reviews: