6
DRAWINGS
All drawings in this Slide Owner’s Manual (Figures 1 through 5) are for illustration
purposes only and are
NOT TO SCALE
.
SUBSEQUENT OWNERS
The Owner’s Manual must remain with the owner of the slide. If the owner changes, the
Owner’s Manual shall be brought to the attention of the new owner.
MANUFACTURER’S PLACEMENT INSTRUCTIONS
THE SLIDE OWNER MUST REVIEW THE MANUFACTURER’S PLACEMENT
INSTRUCTIONS WITH THE INSTALLER TO ENSURE THAT THE
MANUFACTURER’S
INSTALLATION REQUIREMENTS HAVE BEEN MET.
PROPER ASSEMBLY, INSTALLATION, USE, AND SUPERVISION IS ESSENTIAL FOR
PROPER OPERATION AND TO REDUCE THE RISK OF SERIOUS INJURY OR DEATH.
1. The critical dimensions for placement of the Rogue2 slide are as shown in Figures 2
and 3.
A. The slide exit runway surface shall not exceed twenty inches (20”) above the
water surface as shown in Figure 2.
B. The slide shall be positioned so that all water flowing off the runway exit drops
into the pool. Recommended overhang is (3”) inches.
C. The minimum depth of water below the exit lip of the slide shall be three feet (3’)
and increases to four feet six inches (4’-6”) at Pt. A, which is a distance of four
feet six inches (4’-6”) from the exit lip of the slide as shown in Figure 2.
D. A minimum depth of four feet six inches (4’-6”) shall be maintained at a distance
of nine feet (9’) along the extended centerline of the slide from Pt. A. as shown in
Figure 2.
FIGURE 2
DECK/COPING SURFACE
3' MIN.
EXIT
RUNWAY SURFACE
PLUMBLINE
20" MAX.
WATER LEVEL
ENTRANCE
Pt.A
13'-6" MIN.
9' MIN.
4'-6"
4'-6" MIN.
4'-6" MIN.