5
PLANNED MAINTENANCE—QUARTERLY INSPECTION
A8500084
BOTTOM BAR
A8500212
Wall
Anchors
Figure 9
Bottom Bar
Assembly
Breakaway Tab
Yellow Vinyl Loop
With Reversing Edge
NOTE: Remove door from service if any repairs
are needed. All repairs must be done in
accordance with building code.
5. Restore power to the door and return to service.
Fabric Inspection
1. Check the fabric for tears. Repair or replace as
required.
2. Check the windows (optional). If windows were sup-
plied in your door panel, check for dirt or damage
which may impair vision. Clean or replace as
required.
IMPORTANT: Use any good brand of window
cleaner to clean the windows.
DO NOT use abrasive cleaners or
petroleum-based solvents.
3. Ensure the panel is securely fastened to the bottom
bar assembly. Tighten or replace loose or damaged
mounting hardware as required.
4. If the door is configured with wind ribs, make sure
they are in place and tightly secured.
Weather Seal Inspection and Replacement
HEAD ASSEMBLY
NOTE: A weather seal is mounted on the under-
side of the head assembly, on the back
side of the fabric roll.
Inspect the entire length of the weather seal for wear
and damage. Replace if necessary. (See Figure 11)
NOTE: Back Side of Fabric Roll
Figure 10
Wall Anchor Inspection
1. Turn off power to the door.
Weather Seal
The disconnect must be in the OFF posi-
tion and properly locked and tagged
before performing the following proce-
dure.
2. Gain access to wall anchors.
3. Inspect for loose or worn wall anchor(s).
4. Tighten, repair, or replace wall anchor(s) as
needed.
A8500086
Figure 11