background image

5

OPERATION

CAUTION.

Live wires may not be

detected if wires are shielded or in

conduits or behind thick walls or are

more than 40mm away from the scanned surface,

or in concrete, behind a plywood shear wall or

metallic wall covering, or if moisture is present in

the environment or on scanned surface or on the

sensor.
Prior to operating this tool, make sure the area

marked “SENSOR” in the bottom of the housing is

dry. If required, wipe dry using a dry and clean

cloth.
Environmental influences, such as humidity or

closeness to electrical devices, can influence the

measurement accuracy. Surface quality and

condition of the walls (e.g., moisture, metallic

building materials, conductive wallpaper, insulation

materials and tiles) as well as the amount, type,

size and position of the objects can lead to

inaccurate measurements.
If the tool has been subjected to an extreme

temperature change, allow the sensor to adjust to

the ambient temperature before use.
Due to uneven density of tile work on cement board

(used in kitchens, bath/wash rooms) wall sensor

may generate false indications.
Do not expose product to rain or wet conditions or

long term exposure to the sun.
Do not use in harsh environment. Use only in

temperature range -10C° - + 50C°.
To increase battery life, turn off the sensor after

each use.

TURNING THE UNIT ON AND OFF

Press and hold the On/Off button to turn on the

unit, Fig.2. Release the On/Off button to turn the

unit off.

CALIBRATING THE WALL DETECTOR

Hfld the wall detector in your hand away from any

metal objects and live wires. Quickly press the

On/Off button several times unti the metal

detection indicator light and the live wire detection

indicator light illuminate red, Fig.3. When the lights

go out the machine is ready to use.

Note: If the instrument fails to calibrate it could be

due to:
The current measured surface is too wet.
Environmental influences, such as humidity.
Instrument malfunction.

MEASUREMENT OPERATION

With the wall detector flat against the wall and the

On/Off button pressed move the instrument left or

right. When the instrument detects a metal edge,

the metal detection indicator light will change from

green to red and a beep will be heard. Mark this

point with a pencil using the marker point on the

top of the wall detector, Fig.4

Fig. 2

Fig. 3

Fig. 4

Summary of Contents for WWD-100

Page 1: ......

Page 2: ...e your wall detector properly and only for what it is intended you will enjoy years of safe reliable service SPECIFICATIONS Operating temperature 10ºC to 50ºC Storage temperature 20ºC to 70ºC Battery 3 x 1 5V LR44 batteries Wall maximum scanning depth metal 40mm Operating lifetime 6 hours approx Unit size 90 x 38 x 20 5mm THANK YOU FOR BUYING A RYOBI WALL DETECTOR CAUTION Carefully read through th...

Page 3: ...thers who may use this tool SAFETY INSTRUCTIONS DO NOT TAKE ANY ACTION THAT COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE GAS OR WATER PIPE Once object is detected always turn off the electrical power gas and water supplies before drilling hole or driving nail screw into the wall Failure to follow these instructions may result in electrical shock fire and or serious injury Do not ...

Page 4: ...3 DESCRIPTION 2 1 Marker point 2 Sensor area 3 Rating plate 4 Battery compartment 5 Name plate 6 On Off button 7 Live wire detection indicator light 8 Metal detection indicator light 7 4 5 3 8 1 6 ...

Page 5: ... rear of the wall detector and fit the batteries according to the symbol on the battery cover See Fig 1 WARNING Do not attempt to modify this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury BATTERY REPLACEMENT If the instrument does not switch on replace the batteries as previously stated above BATTERY DISP...

Page 6: ...ensor may generate false indications Do not expose product to rain or wet conditions or long term exposure to the sun Do not use in harsh environment Use only in temperature range 10C 50C To increase battery life turn off the sensor after each use TURNING THE UNIT ON AND OFF Press and hold the On Off button to turn on the unit Fig 2 Release the On Off button to turn the unit off CALIBRATING THE WA...

Page 7: ...banging the unit on the wall may generate static electricity and cause a false reading Fig 5 MAINTENANCE WARNING Do not operate the detector until the battery compartment cover is in place and fastened GENERAL MAINTENANCE This instrument is designed to provide years of dependable service if the following care instructions are performed Keep the wall detector dry and free from dust Use and store th...

Page 8: ...ed of with your general household waste Some chemicals contained within electrical electronic products or batteries can be harmful to health SYMBOLS SYMBOL SIGNAL MEANING DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTI...

Reviews: