3.  Remove the cartridge fi lter and dust bag, and install 

a foam fi lter over the fi lter basket and place the top 
section back on the tank (Fig. 9).

4.  DO NOT use the cartridge fi lter for wet or sharp 

materials. Fit the desired nozzle to the vacuum hose 
(Fig. 12).

5.  Ensure that the switch is in the ‘O’ (OFF) position 

before plugging the power cord into the power 
outlet.

6.  Turn the motor on by fl ipping the switch to the “I” 

(ON) position (Fig. 14).

7.  After use, fl ip the switch to the “O” position (Fig. 15) 

and unplug the power cord, then empty and dry the 
tank (Fig. 16).

 WARNING

The foam fi lter must be removed after wet 
vacuuming, and a cartridge fi lter must be installed 
before dry vacuuming again.

IMPORTANT!

When vacuuming large quantities of liquids, do not 
immerse the nozzle completely in the liquid; leave a gap 
at the tip of the nozzle opening to allow air infl ow.
The machine is fi tted with a fl oat valve that stops the 
suction action when the container reaches its maximum 
capacity. You will notice an increase in motor speed.
When this happens, turn off the machine, disconnect 
from power supply, and drain the liquid into a suitable 
receptacle or drain. To continue vacuuming, refi t the 
container with the drain cap. After wet vacuuming, turn 
the machine off and remove plug from power supply.
Empty the container, clean and dry the inside and 
outside before storage.

BLOWER OPERATION

This Wet/Dry Vac has blowing capabilities.
To use the blower feature follow the instructions listed.

 WARNING

Always wear safety goggles before using blower.
Keep bystanders clear from blowing debris.
Wear a dust mask if blowing creates dust that might 
be inhaled

1.  Insert the large end of the hose into the blower 

connection in the top of the motor housing (Fig. 17).

2.  Fit the crevice tool to the vacuum hose (Fig. 18). 

Ensure the power switch is turned off and plug in the 
power supply.

3.  Turn the motor on by fl ipping the switch to the “I” 

(ON)position (Fig. 14).

4.  The unit will now blow through the vacuum hose and 

can be used to clear obstructions within the hose. 
(Fig. 19)

5.  Once you have fi nished operation, fl ip the switch to 

the ‘O’ (OFF) position and unplug the power cord 
from the power outlet. (Fig. 15)

 WARNING

If after a few seconds the hose continues to be 
blocked, turn off the unit and clear the hose 
manually.

MAINTENANCE

1.  Verify that the power cord is disconnected from the 

outlet. Disconnect the hose from the container 
(Fig. 20).

2.  Undo the clamps and remove the top section from 

the container (Fig. 21).

3.  Clear all dirt or debris from the container and hose 

(Fig. 22).

4.  Clean the cartridge fi lter by gently tapping or 

brushing dirt off. For optimal performance it is 
recommended to regularly change this fi lter 
depending on level of use (eg. 3-6 months). 
Cartridge fi lter is not washable.

5.  Use a mild soap and water solution to wash foam 

fi lter and rinse with clean water. (Fig. 23)

6.  Check the hoses, attachments, and power cord to 

verify that they have not been damaged.

IMPORTANT! 
CHANGE THE DUST FILTER REGULARLY. IF THE 
MACHINE IS USED WITHOUT THE DUST FILTER, 
THE MOTOR WILL BURN OUT AND THE WARRANTY 
WILL BE VOIDED. ALWAYS KEEP SPARE FILTERS 
ON HAND.

RVC-1218P-G - Version01.indd   11

RVC-1218P-G - Version01.indd   11

21.05.2016   19:19:39

21.05.2016   19:19:39

Summary of Contents for RVC-1218P-G

Page 1: ...RVC 1218P G OWNER S OPERATING MANUAL WET AND DRY VACUUM CLEANER RVC 1218P G Version01 indd 1 RVC 1218P G Version01 indd 1 21 05 2016 19 19 38 21 05 2016 19 19 38...

Page 2: ...nnection 11 Filter basket 12 Safety float valve 13 Cartridge filter non washable 14 Cartridge filter cap 15 ON OFF switch 16 Connection for the vacuum hose 17 Clamp x2 18 Tank Fig 1 Components list 10...

Page 3: ...3 DESCRIPTION 2 1 RVC 1218P G Version01 indd 3 RVC 1218P G Version01 indd 3 21 05 2016 19 19 38 21 05 2016 19 19 38...

Page 4: ...4 DESCRIPTION RVC 1218P G Version01 indd 4 RVC 1218P G Version01 indd 4 21 05 2016 19 19 38 21 05 2016 19 19 38...

Page 5: ...5 DESCRIPTION RVC 1218P G Version01 indd 5 RVC 1218P G Version01 indd 5 21 05 2016 19 19 38 21 05 2016 19 19 38...

Page 6: ...6 Fig 23 DESCRIPTION Fig 20 Fig 21 Fig 22 RVC 1218P G Version01 indd 6 RVC 1218P G Version01 indd 6 21 05 2016 19 19 38 21 05 2016 19 19 38...

Page 7: ...essential that you read the instructions in this manual before operating this machine Subject to technical modi cations RVC 1218P G Version01 indd 7 RVC 1218P G Version01 indd 7 21 05 2016 19 19 39 21...

Page 8: ...only to a 240V alternating current receptacle Make sure that the correct dust bag has been inserted securely in its holder before using the appliance The wrong dust bag or incorrectly installed dust...

Page 9: ...not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly quali ed persons in order to avoid a hazard Electrical power should be...

Page 10: ...ny PACKAGING CONTENT See Fig 2 Fig 4 Carefully unpack the contents of the box Hold the two clamps which hold the upper section in its position and fold them upwards Loosen the clamps remove the upper...

Page 11: ...re using blower Keep bystanders clear from blowing debris Wear a dust mask if blowing creates dust that might be inhaled 1 Insert the large end of the hose into the blower connection in the top of the...

Page 12: ...o reduce the risk of personal injury unplug the cleaner before performing maintenance troubleshooting checks Problem Cause Solution The appliance doesn t work No power Check the power supply Functiona...

Page 13: ...13 RVC 1218P G Version01 indd 13 RVC 1218P G Version01 indd 13 21 05 2016 19 19 39 21 05 2016 19 19 39...

Page 14: ...14 RVC 1218P G Version01 indd 14 RVC 1218P G Version01 indd 14 21 05 2016 19 19 39 21 05 2016 19 19 39...

Page 15: ...15 RVC 1218P G Version01 indd 15 RVC 1218P G Version01 indd 15 21 05 2016 19 19 39 21 05 2016 19 19 39...

Page 16: ...6 V01 Copyright 2016 Techtronic Industries GmbH Max Eyth Stra e 10 71364 Winnenden Germany 49 0 7195 12 0 RVC 1218P G Version01 indd 16 RVC 1218P G Version01 indd 16 21 05 2016 19 19 39 21 05 2016 19...

Reviews: