background image

INSTALLATION OF THE PRESSURE LINE

The pressure line conveys the liquids to be discharged 

from the pump to the point of withdrawal. To avoid 

dynamic flow losses, one should use a pressure line 

having at least the same diameter as the water outlet (1) 

of the pump.

3

 WARNING

 WARNING

Please make sure that the pump will cut out as soon

has reached the cut-out level.

Also it must be made sure that the floating switch 

can move freely.

 The pump MUST be attended when used in this mode 

as the motor receives no cooling and can over heat. 

HOW TO POSITION THE PUMP

1.  Screw the connection adaptor (10) into the pump 

outlet.

2.  Screw  the  connection  port  into  the  connection 

adaptor.

3.  Fix a hose to the combination nipple, use a hose 

clamp to secure the hose.

STATIONARY INSTALLATION

If the unit is used in a stationary installation, rigid pipes 

have proven to be the ideal choice for the pressure 

lines. In this type of installation, we recommend that 

you incorporate a check valve (non-return valve) in the 

pressure line immediately following the pump outlet 

To facilitate maintenance work, we also recommend 

the installation of a stop cock valve downstream of the 

in that closing the stop cock will prevent the pressure 

line from running dry after the disassembly of the pump.

HOW TO SET FLOAT SWITCH

The pump is fitted with a float switch, which controls 

1.  When  the  float  switch  is  about  30°  higher  than 

horizontal (start up level) or above the handle, the 

pump will turn ‘on’ and operate. 

(Fig. 1)

2.  When  the  float  switch  is  30°  lower  than  the 

horizontal or below the handle, the pump will turn 

‘off’. 

(Fig. 2)

3.  To set the pump to switch off at a lower water level, 

insert the float switch cable into the adjuster Note: 

There must be a minimum of 100mm of cable from 

the adjuster to the float. 

(Fig. 3)

4.  Manual mode: when the float is manually secured at 

ON position, the pump can draw down to a minimum 

level of 54mm (at 0m delivery height) 

(Fig. 4)

 

When positioning the pump, please make sure that 

the max. immersion depth indicated in the technical 

data will not be exceeded.

 

Likewise,  please  make  sure  that  the  minimum 

selfpriming level is not fallen short of. If everything 

is  properly  set,  the  water  level  may  decrease 

down to the minimum suction level once the pump 

is operating. Please position the pump on solid 

ground. Avoid placing it on lose stones or sand.

 

When positioning the pump, elevate it from the 

bottom such that sediment and debris will not be 

sucked into the inlet. This will protect the impellers 

as well as maintain flow performance

 

To position, lift up or carry the pump, please use 

only the carrying handle(7).

 

If required for lowering or raising the pump, you 

must  connect  a  suitable  lowering  rope  to  the 

carrying handle. Do NOT lift pump using the hose, 

power cord or float cable.

ELECTRICAL CONNECTION

 

The unit is equipped with a power connection cable 

and a plug. It must only be replaced by qualified 

staff to avoid any danger. Please do not use the 

power cable to carry the pump, and do not use this 

cable to pull off the plug from the socket, either. 

Protect the power cable and mains plug from heat, 

oil or sharp edges.

 

The values stated in the technical details have 

to correspond to the mains voltage. The person 

responsible for the installation has to make sure that 

the electrical connection is earthed in compliance 

with the applicable standards.

 

The electrical connection has to be equipped with 

a highly sensitive residual current circuitbreaker 

(FIswitch) :

 Δ

 = 30 mA.

 

If extension cables are used, their cross-section 

must not be smaller than that of rubbersheathed 

cables of the H07RN-F (3 x 1,0 mm²) short code.

The mains socket and the plugand-socket elements 

have to be in splash water-proof design.

PUTTING INTO OPERATION

 

Nobody must be in the water while the pump is 

running.

 

The pump must only be operated in the performance 

range indicated on the type plate.

 

Dry-running  -  i.e.  operating  the  pump  without 

discharging  water  is  to  be  avoided  since  the 

absence  of  water  may  cause  the  pump  to  run 

hot. This may cause considerable damage on the 

device.

 

Please  make  sure  that  the  electrical  plug 

connections are in flood-proof area.

 

As long as the device is connected to the electrical 

mains, one must never reach with one’s hands into 

the opening of the pump.

 

Please inspect the pump visually prior to each use.

 

This applies in particular to the mains connection 

line and the mains plug. Make sure that all screws 

are firmly tightened, and verify the perfect condition 

of all connection. A damaged pump must not be 

used. In any case of damage, the pump has to be 

Summary of Contents for RSSS1000

Page 1: ...RSSS750 RSSS1000 750W 1000W STAINLESS STEEL SUBMERSIBLE PUMP RSSS750 RSSS1000...

Page 2: ...mp base 3 Suction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 1 11 10 9 2 4 3 5 6 7 8 R...

Page 3: ...ction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 12 Thread seal tape 1 11 10 9 2 4 3 5...

Page 4: ...DESCRIPTION 30 30 100mm minimum PUSH START STOP A B C Fig 1 Fig 3 Fig 2 Fig 4...

Page 5: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 6: ...ep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Do not ov...

Page 7: ...re that the pump is not exposed to any form of weight vibration or tension Moreover the connection lines must not contain any kinks Avoid inserting hands into the inlets outlets of the water pump whil...

Page 8: ...el may decrease down to the minimum suction level once the pump is operating Please position the pump on solid ground Avoid placing it on lose stones or sand When positioning the pump elevate it from...

Page 9: ...and thus cause considerable damage Therefore the pump must be removed from the liquid being discharged and fully drained when temperatures are below the freezing point of the liquid Please store the p...

Page 10: ...ax Water Flow Max Working Temp Max Particle Size Cable Length Rated Power Max Head Max Immersion Depth Max Water Flow Max Working Temp Max Particle Size Cable Length 750W 9m 7m 17 000L hr 35 C 35mm 10...

Page 11: ...clogged or kinked Remove possible congestion kink in the line Air penetrates into the pump body Start pump several times so that the entire air will be driven out Check valve non return valve if pres...

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...

Reviews: