 WARNING

The water pump together with associated pipework 

operate under pressure. Do not disconnect water 

pump or pipework until internal pressure has been 

released. Failure to do this could result in personal 

injury and damage to property.

2

 WARNING

 WARNING

 WARNING

The pump is not suited to discharge salt water, 

sewage, flammable, caustic or hazardous liquids. 

Please observe the max. temperature of the liquids 

to be discharged stated in the technical data.

Inside the pump, lubricants are used which may 

contaminate the liquids being discharged in case 

of any improper operation or damage of the device. 

The lubricants used are biologically degradable and 

nonhazardous to health.

During the entire process of installation, the device 

must not be connected to the electrical mains. The 

pump and the entire connection system have to be 

protected from frost.

INTENDED USE

INSTALLATION

SYMBOLS DEFINITION ON THE PRODUCT

 WARNING

Make sure the pump is disconnected from electric 

power  supply  before  performing  maintenance 

procedures.

MAINTENANCE

CLEANING THE PUMP HOUSING

Use a moist cloth to wipe down the pump housing. 

Allow to dry thoroughly before storing in a dry location 

that is protected from bad weather conditions.

 

Ensure  all  connections  are  leak  free.  Use  the 

included  thread  seal  tape  (12)  (included  with 

RSSS1000  only)  or  a  suitable  sealant  on  the 

connection thread.

 

When  tightening  threaded  connections,  please 

do not apply excessive force which may cause 

damage.

 

When  laying  the  connection  pipes,  you  should 

make sure that the pump is not exposed to any 

form of weight, vibration or tension. Moreover, the 

connection lines must not contain any kinks.

 

Avoid inserting hands into the inlets/outlets of the 

water pump while it is connected to power.

 

Before using the water pump, always inspect it 

visually. Do not use the pump if it is cracked and/or 

damaged. 

 

The water pump has a built-in thermal protection 

overload  switch.  The  water  pump  stops  if  an 

overload occurs. The motor restarts automatically 

after it has cooled down.

 

The pump must not be used when people are in the 

water.

 

Never work or perform maintenance on the pump 

without first making sure it has been disconnected 

from the mains power.

 

Pollution of the liquid could occur due to leakage of 

lubricants.

Important: 

Avoid inserting hands into the mouth of 

the pump if it is connected to the mains. The electrical 

connection must always be made in a dry area. Make 

sure that electrical connections are protected from 

inundations.

Protect the plug and the power cable from heat, oil or 

sharp edges.

 

A  distinctive  feature  of  this  pump  is  that  it  can 

briefly operated (max. 4 min.) with liquids with a 

temperature up to 95°C (see Technical data).

 

RYOBI Submersible dirty water pumps are highly 

efficient electrical pumps for discharging clear or 

dirty water containing solids up to the maximum size 

specified in the technical details.

 

This pump is intended for discharging clear or dirty 

water containing solids up to the maximum size 

35mm

 

Typical applications for waste water submersible 

pumps are: Emptying ponds, tanks, storage tanks, 

and waste water pits, emergency drainage in the 

event  of  flood  etc. This  product  is  intended  for 

household use only, not for extended continuous 

operation.

Summary of Contents for RSSS1000

Page 1: ...RSSS750 RSSS1000 750W 1000W STAINLESS STEEL SUBMERSIBLE PUMP RSSS750 RSSS1000...

Page 2: ...mp base 3 Suction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 1 11 10 9 2 4 3 5 6 7 8 R...

Page 3: ...ction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 12 Thread seal tape 1 11 10 9 2 4 3 5...

Page 4: ...DESCRIPTION 30 30 100mm minimum PUSH START STOP A B C Fig 1 Fig 3 Fig 2 Fig 4...

Page 5: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 6: ...ep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Do not ov...

Page 7: ...re that the pump is not exposed to any form of weight vibration or tension Moreover the connection lines must not contain any kinks Avoid inserting hands into the inlets outlets of the water pump whil...

Page 8: ...el may decrease down to the minimum suction level once the pump is operating Please position the pump on solid ground Avoid placing it on lose stones or sand When positioning the pump elevate it from...

Page 9: ...and thus cause considerable damage Therefore the pump must be removed from the liquid being discharged and fully drained when temperatures are below the freezing point of the liquid Please store the p...

Page 10: ...ax Water Flow Max Working Temp Max Particle Size Cable Length Rated Power Max Head Max Immersion Depth Max Water Flow Max Working Temp Max Particle Size Cable Length 750W 9m 7m 17 000L hr 35 C 35mm 10...

Page 11: ...clogged or kinked Remove possible congestion kink in the line Air penetrates into the pump body Start pump several times so that the entire air will be driven out Check valve non return valve if pres...

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...