background image

3

IMPORTANT SAFETY INSTRUCTIONS

This compressor is designed for tyre inflation, the
operation of pneumatic tools, spray painting and
spraying non-corrosive cleaning agents. Do not use
this compressor for filling cylinders for breathing or
diving apparatus. Compressed air from this
compressor must not be used for pharmaceutical,
food or health applications.

When spraying flammable liquids such as paint and
non-corrosive cleaning agents the distance
between the compressor and the work area must
be a minimum of 4 metres. When spraying liquids
always wear a suitable face mask designed for
protection against the liquid being sprayed. Always
wear approved safety glasses.

Do not attempt to modify the compressor or any
pneumatic tools in any way. Use only accessories
and pneumatic tools that are rated for the capacity
of the compressor. Never leave the compressor
pressurised.

Always transport the compressor by lifting or
pulling it with the appropriate grips or handles.

Do not insert your fingers or other objects inside
the motor housing to avoid physical damage or
damage to the compressor.

If any part of the compressor is damaged, it should
be carefully checked to determine that it will
operate correctly and perform its intended function.
Check for the alignment of parts, damage to parts,
air leaks and any other conditions that may affect
its operation. A guard or any other part that is
damaged or defective should be properly repaired
or replaced by an authorised service centre.
Defective pressure switches must be replaced prior
to further use of the compressor.

WARNING.

This compressor must be

connected to a power socket that is
safeguarded by a suitable circuit breaker
or fuse.

To reduce the risk of electric shock, do not expose
to rain. Store indoors.

Inspect tanks yearly for rust, pin holes, or other
imperfections that could cause it to become unsafe.
Never weld or drill holes in the air tanks.

Only use recommended parts. To avoid the risk of
bursting, only hoses with a rated pressure of 10
bar, or more should be used. Never attempt to re-
pair faulty hoses.

Avoid kinking or trapping the air hose. Always
replace faulty hoses - never attempt a repair if a
leak is detected.

Make sure the hose is free of obstructions or
snags. Entangled or snarled hoses can cause loss
of balance or footing and may become damaged.

Do not operate this air compressor if it does not
contain a legible warning label.

Always disconnect the air supply and power supply
before making adjustments, servicing a product, or
when a product is not in use.

Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one
heavy enough to carry the current your product will
draw. A wire gauge size (A.W.G.) of at least 14 is
recommended for an extension cord 25 feet (7.6m)
or less in length. A cord exceeding 50 feet (15.2m)
is not recommended. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord. An undersized cord will cause a
drop in line voltage resulting in loss of power and
overheating.

Never store a tool with air connected. Storing the
tool with air connected can result in unexpected
firing and possible serious personal injury.

Protect your lungs. Wear a face or dust mask if the
operation is dusty. Following this rule will reduce
the risk of serious personal injury.

Keep the motor vent clear and free from dust, wipe
regularly to maintain an adequate supply of clean
air to the air compressor.

If the power supply cord is damaged, it must be
replaced only by the manufacturer or by an
authorized service center to avoid risk.

SAVE THESE INSTRUCTIONS

1) WORK AREA

a)

Keep your work area clean and well lit.

Cluttered benches and dark areas invite
accidents. Floor must not be slippery from wax
or dust.

b)

Do not operate air compressors in explosive
atmospheres, such as in the presence of
flammable liquids, gases, or dust.

Power

tools create sparks which may ignite the dust or
fumes.

Summary of Contents for RC-3150B

Page 1: ...njoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz Rated power 2 2kW 3 0HP Receiver capacity 150l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500m...

Page 2: ...s and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lub...

Page 3: ...e Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty...

Page 4: ...with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer an...

Page 5: ...t is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substa...

Page 6: ...Castor wheel 7 Wheel x 2 8 Drain valve 9 Air receiver tank 10 Oil drain plug 11 Dipstick 12 Air filter 13 Air outlet pressure regulator 14 Air outlet quick release connector regulated 15 Air outlet p...

Page 7: ...NTS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Castor wheel Rubber foot and rubber foot fixing nut Dipstick Operator s Manual WARNING If any parts are damaged or missing do not opera...

Page 8: ...ase all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compresso...

Page 9: ...used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insuffic...

Page 10: ...on pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compress...

Page 11: ...t the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is wo...

Page 12: ...ndensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighte...

Page 13: ...move the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary th...

Page 14: ...it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampe...

Page 15: ...hten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve t...

Page 16: ...dous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not op...

Page 17: ...17 NOTES...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ......

Reviews: