background image

11

OPERATION

CONNECTING/DISCONNECTING AIR HOSE

WARNING.

Never exceed the air tool’s

pressure rating as recommended by the
manufacturer. When using this air
compressor as an inflation device,
always follow the maximum inflation
guidelines stated by the manufacturer of
the item being inflated.

Make sure the air compressor is off and
unplugged.

Rotate pressure regulator knob fully in the
counter-clockwise direction so that the outlet
pressure is at zero (0) psi.

Connect a hose to the compressor using the hose
to compressor quick release connector (Fig.10).
Make sure to push the air fitting fully into the
coupler until the sleeve springs forward to lock in
place.

When using the regulated air output first determine
the working pressure of the accessory by referring
to the accessory manual. Slowly open the air outlet
pressure regulator (Fig.11) at the same time
observing the air outlet pressure gauge until the
pressure gauge reads the minimum pressure for
the accessory.

Fine adjustments to the air pressure can be made
until the accessory is working at its optimum
performance.

When the correct operating air pressure has been
set, the air outlet pressure regulator can be locked
by tightening the locking ring (Fig.12).

Do not exceed the maximum rated air pressure for
the accessory.

NOTE:

Always use the minimum amount of

pressure necessary for your application. Using a
higher pressure than needed will drain air from the
tank more rapidly and cause the unit to cycle on
more frequently.

To disconnect an air hose or an air tool:

Confirm that the outlet pressure is at zero (0) psi.

When disconnecting a hose from the quick release
connector, always firmly hold the fitting end of the
hose.

Push back on the release sleeve on the quick
release connector. With a firm grip, pull out the
quick-connect air fitting that is attached to the quick
release connector, Fig.13.

Fig. 10

Fig. 11

Fig. 12

Fig. 13

Summary of Contents for RC-3150B

Page 1: ...njoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz Rated power 2 2kW 3 0HP Receiver capacity 150l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500m...

Page 2: ...s and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lub...

Page 3: ...e Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty...

Page 4: ...with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer an...

Page 5: ...t is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substa...

Page 6: ...Castor wheel 7 Wheel x 2 8 Drain valve 9 Air receiver tank 10 Oil drain plug 11 Dipstick 12 Air filter 13 Air outlet pressure regulator 14 Air outlet quick release connector regulated 15 Air outlet p...

Page 7: ...NTS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Castor wheel Rubber foot and rubber foot fixing nut Dipstick Operator s Manual WARNING If any parts are damaged or missing do not opera...

Page 8: ...ase all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compresso...

Page 9: ...used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insuffic...

Page 10: ...on pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compress...

Page 11: ...t the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is wo...

Page 12: ...ndensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighte...

Page 13: ...move the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary th...

Page 14: ...it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampe...

Page 15: ...hten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve t...

Page 16: ...dous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not op...

Page 17: ...17 NOTES...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ......

Reviews: