background image

2

English

 WARNING

Ensure the air supply is clean and does not exceed 
90psi while operating the tool. Too high an air pressure 
and unclean air will shorten the product life due to 
excessive wear, and may be dangerous, causing 
damage and/or personal injury.

LUBRICATION

An automatic in-line 

fi

 lter-regulator-lubricator 

is 

recommended (Fig. 8) as it increases tool life and keeps 
the tool in sustained operation. The in-line lubricator 
should be regularly checked and 

fi

 lled with air tool oil.

Proper adjustment of the in-line lubricator is performed by 
placing a sheet of paper next to the exhaust ports and 
holding the throttle open approximately 30 seconds. The 
lubricator is properly set when a light stain of oil collects 
on the paper. Excessive amounts of oil should be avoided. 
It becomes necessary to store the tool for an extended 
period of time (overnight, weekend, etc.), it should receive 
a generous amount of lubrication at that time. The tool 
should be run for approximately 30 seconds to ensure oil 
has been evenly distributed throughout the tool. The tool 
should be stored in a clean and dry environment.

 

It is most important that the tool be properly 
lubricated by keeping the air line lubricator filled 
and correctly adjusted. Without proper lubrication 
the tool will not work properly and parts will wear 
prematurely.

 

Use correct lubricant in the air line lubricator. The 
lubricator should be of low air flow or changing air 
flow type, and should be kept filled to the correct 
level. Use only recommended lubricants, specially 
made for pneumatic applications. Substitutes may 
harm the rubber compounds in the tools O-rings 
and other rubber parts.

IMPORTANT!

See Figure 8.

If a 

fi

 lter/regulator/lubricator is not installed on the air 

system, air operated tools should be lubricated at least 
once a day or after 2 hours work with 2 to 6 drops of oil, 
depending on the work environment, directly through 
the male 

fi

 tting in the tool housing.

LOADING AND OPERATION

 WARNING

Drain  the  air  tank  daily.  Water  in  the  air  line  will 
damage the tool.

 

Clean air inlet filter weekly.

 

Line pressure should be increased to compensate for 
unusually long air hoses (over 8 metres). The hose 
diameter should be 9.52 mm (3/8”) I.D.

 

Keep hose away from heat, oil and sharp edges. Check 
hose for wear, and make certain that all connections 
are secure.

 

Air tools should not be used in a potentially explosive 
environment.

 

There is a risk of explosion or fire due to the material 
being processed. 

 

There is a  risk of cutting.

 

There is a risk of drawing in or trapping of long hair, 
loose clothing.

 

WARNING! Cutting off tools shall not be used.

 

Personal protection and dust collection device shall be 
chosen with regard to the material being worked upon.

 

If the tool cannot be used anymore, make sure to 
dispose of it so as not to impose hazards to people 
and the environment.

 

No spare parts are to be used, when these affect the 
health and safety of operators.

 

There is a risk of a whipping compressed air hose.

MAINTENANCE

 WARNING

Disconnect tool from air supply before changing 
accessories, servicing or performing maintenance. 
Replace or repair damaged parts. Use genuine parts 
only. Non-authorized parts may be dangerous.

 

Keep the tool safe by regular maintenance.

 

Lubricate the tool daily with a few drops of air tool oil 
dripped into the air inlet.

 

Clean the tool after use. Do not use worn out or 
damaged sockets.

 

Loss of power or erratic action may be due to the 
following:

 

– Excessive drain on the air line. Moisture or 

restriction in the air pipe. Incorrect size or type of 
hose connectors. To remedy check the air supply

Reviews: