background image

1

gENERAl SAFEty RUlES

 

■ For multiple hazards, read and understand the safety 

instructions before installing, operating, repairing, 

maintaining, changing accessories on, or working 

near, the air tool. Failure to do so can result in serious 

bodily injury.

 

■ Only qualified and trained operators should install, 

adjust or use the air tool.

 

■ Do not modify this air tool. Modifications can reduce 

the effectiveness of safety measures and increase the 

risks to the operator.

 

■ Do not discard the safety instructions; give them to the 

operator.

 

■ Do not use the air tool if it has been damaged.

 

■ Tools shall be inspected periodically to verify that the 

ratings and markings required by this part of EN 792-

13 are legibly marked on the tool. The employer/user 

shall contact the manufacturer to obtain replacement 

marking labels when necessary.

pROjEctIlE hAzARdS

 

■ Be aware that the failure of the work piece, or 

accessories, or even of the fastener driving tool itself, 

can generate high-velocity projectiles.

 

■ Always wear impact-resistant eye protection during 

the operation of the air tool. The grade of protection 

required should be assessed for each use.

 

■ Ensure that the work piece is securely fixed.

ENtANglEMENt hAzARdS

Choking, scalping and/or lacerations can occur if loose 

clothing, personal jewellery, neck wear, hair or gloves are 

not kept away from the tool and accessories.

OpERAtINg hAzARdS

 

■ Operators and maintenance personnel shall be 

physically able to handle the bulk, weight and power 

of the tool.

 

■ Hold the tool correctly; be ready to counteract normal 

or sudden movements and have both hands available.

 

■ Maintain a balanced body position and secure footing.

 

■ Release the start-and-stop device in the case of an 

interruption of the compressed air supply.

 

■ Use only lubricants recommended by the manufacturer.

 

■ Personal protective safety glasses shall be used; suitable 

gloves and protective clothing are recommended.

REpEtItIVE MOtIONS hAzARdS

 

■ When using an air tool to perform work-related 

activities, the operator can experience discomfort in 

the hands, arms, shoulders, neck or other parts of the 

body.

 

■ While using an air tool, the operator should adopt a 

comfortable posture while maintaining a secure footing 

and avoiding awkward or off-balanced postures. The 

operator should change posture during extended 

tasks, which can help avoid discomfort and fatigue.

 

■ If the operator experiences symptoms, such as 

persistent or recurring discomfort, pain, throbbing, 

aching, tingling, numbness, burning sensations or 

stiffness, these warning signs should not be ignored. 

The operator should tell the employer and consult a 

qualified health professional.

AccESSORy hAzARdS

 

■ Disconnect the air tool from the compressed air line 

before fitting or changing the fasteners or accessory.

 

■ Use only sizes and types of accessories and 

consumables that are recommended by the air tool 

manufacturer; do not use other types or sizes of 

accessories and consumables.

WORkplAcE hAzARdS

 

■ Slips, trips and falls are major causes of workplace 

injury. Be aware of slippery surfaces caused by the 

use of the tool and also of trip hazards caused by the 

air line.

 

■ Proceed with care in unfamiliar surroundings. There 

can be hidden hazards, such as electricity or other 

utility lines.

 

■ The air tool is not intended for use in potentially 

explosive atmospheres and is not insulated against 

coming into contact with electric power.

 

■ Ensure that there are no electrical cables, gas pipes, 

etc., that can cause a hazard if damaged by use of 

the tool.

NOISE EMISSION

The characteristic noise values for the fastener driving tool 

have been determined in accordance with EN12549:1999 

and EN ISO4871 "Acoustics-Noise test code for fastener 

driving tools-Engineering method" (see Specifications).
These values are tool-related characteristic values and do 

not represent the noise development at the point of use. 

Noise development at the point of use will for example 

depend on the working environment, the work piece, the 

work piece support, the number of driving operations, etc.
Depending in the conditions at the workplace and the form 

of the workplace, individual noise attenuation measures 

may need to be carried out, such as placing work pieces 

on sound-damping supports, preventing work piece 

vibration by means of clamping or covering, adjusting 

to the minimum air pressure required for the operation 

involved, etc.
In special cases it is necessary to wear hearing protection 

equipment.

Summary of Contents for RA-NBS1832-S

Page 1: ...ailer Stapler 2 in 1 Operator s MANUAL Original instructions RA NBS1832 S Important It is essential you read the instructions in this manual before starting and operating this machine Subject to techn...

Page 2: ...ig 5 1 2 1 3 2 1 5 4 6 Description 1 Nitto style coupler 2 No mar pad 3 Safety yoke 4 Exhaust cap 5 Air supply 6 Magazine 7 Nails 8 Staples 9 Trigger 10 Depth adjustment knob 11 Flat blade screwdriver...

Page 3: ...Fig 11 Fig 10 Fig 9 Fig 8 3 2 1 9 10 7 8 6 12 11 Fig 7 1 3 2 8 6...

Page 4: ...Fig 12 Quick connector Quick connector Lubricator Filter Cut off valve Regulator 0 8 5 bar Quick coupler Tool Air compressor Quick coupler Air hose...

Page 5: ...l the operator should adopt a comfortable posture while maintaining a secure footing and avoiding awkward or off balanced postures The operator should change posture during extended tasks which can he...

Page 6: ...nstructions may be used for the maintenance of fastener driving tools Only spare parts specified by the manufacturer or his authorised representative shall be used Repairs shall be carried out only by...

Page 7: ...iameter of at least 19 mm and a corresponding large diameter where relatively long pipelines or multiple users are involved Compressed air pipelines should be laid so as to form a gradient highest poi...

Page 8: ...ments Connect the product to the air hose Push the tool against the work surface and squeeze the trigger to drive a fastener Do not use any additional force upon the product WARNING Ensure the air sup...

Page 9: ...s the tool should be lubricated with air tool oil before connecting the tool to an air supply Add air tool lubricant into the air fitting on the tool once daily with minimal use or twice a day with he...

Page 10: ...cycle when the tool is first connected to the air supply Always connect the tool to a pressurized air supply before loading fasteners to prevent injury from unintended cycling Always make sure the too...

Page 11: ...essure Having checked that the fastener driving tool is functioning correctly apply the tool to a work piece and actuate the trigger Check whether the fastener has been driven into the work piece in a...

Page 12: ...t any time let brake fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious persona...

Page 13: ...nt of the in line lubricator is performed by placing a sheet of paper next to the exhaust ports and actuate the tool 10 15 times without fasteners loaded The lubricator is properly set when a light st...

Page 14: ...damaged O rings or seals Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Verify adequate air supply Inadequate lubrication Lubricate tool Worn or damaged O rings or...

Page 15: ...Sealing ring 10 O ring 18 x 2 65 32 Adjustment nut I 54 Orientation pin 76 End cap I 11 Compressed spring 33 Snap retainer 55 Pin 77 End cap II 12 O ring 35 5 x 2 3 34 Adjustment nut II 56 Bolt M4 x 1...

Page 16: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand...

Reviews: