background image

9 — English

OPERATION

INSTALLING/REMOVING POWER CORD

See Figure 2, page 13.

WARNING:

Do not route cord under carpets, rugs, runners, furniture, 
or appliances and always route cord away from traffic 
areas to prevent a tripping hazard.

  Insert the female end of the power supply cord into the 

product as shown until it clicks into place.

  Connect the male end of the power cord to the power 

source.

  Make sure the power cord is secured before beginning 

operation.

  To remove the power cord, unplug the cord from the 

power source.

  Press the release button on the top of the female end of 

the power supply cord and remove from the tool.

DIRECTION OF ROTATION SELECTOR

(CLOCKWISE/COUNTERCLOCKWISE/CENTER LOCK)

See Figure 3, page 13.

Set the direction of rotation selector in the 

OFF

 (center lock) 

position to lock the switch trigger and help prevent accidental 
starting when not in use.
Position the direction of rotation selector to the left of the 
switch trigger in the 

F/R

 (forward/retract) position to rotate 

the cable clockwise. Position the selector to the right of the 
switch trigger in the 

N

 (neutral) position to rotate the cable 

counterclockwise.

NOTE:

 The tool will not run unless the direction of rotation 

selector is pushed fully to the left or right.

NOTE:

 For optimal performance, position both the direction of 

rotation selector and the direction of feed collar as described 
later in the 

Feed and Rotation Chart

.

NOTICE:

To prevent gear damage, always allow the cable to come to 
a complete stop before changing the direction of rotation.

WARNING:

Hybrid tools are always in operating condition. Therefore, 
lock the switch trigger when not in use or carrying at your 
side, when installing or removing the battery pack, when 
connecting or disconnecting the power cord, and when 
manually advancing or retracting the cable. Failure to 
follow these instructions could result in serious personal 
injury.

VARIABLE SPEED SWITCH TRIGGER

See Figure 4, page 14.

The variable speed switch trigger delivers higher speed with 
increased trigger pressure and lower speed with decreased 
trigger pressure.
To turn the tool 

ON

, depress the switch trigger. To turn it 

OFF

, release the switch trigger and allow the cable to come 

to a complete stop.

FEED DIRECTION SELECTOR COLLAR

See Figures 5 and 6, page 14.

The drain auger has three operating modes: forward (

F

), 

neutral (

N

), and retract (

R

). In the forward (

F

) position, 

squeezing the switch trigger will rotate and advance the 
cable. When the tool is in retract (

R

) position, the cable 

will rotate and retract as the switch trigger is squeezed. If 
the drain auger is in neutral (

N

), the cable will not rotate, 

advance, or retract. 

NOTE: Never run the tool while the collar is pushed in 
and in the neutral (N) position. Doing so will cause the 
cable to kink.
To switch between modes:

 

Lock the switch trigger by placing the direction of rotation 
selector in 

OFF

 (center lock) position.

 

Pull the feed direction selector collar away from the tool 
and rotate it until the feed indicator is pointing at your 
desired operating mode.

 

Push the collar toward the drum until it clicks into place. 

 

NOTE:

 The drum will rotate in the same direction 

regardless of the direction of feed.

 

NOTE:

 For optimal performance, position both the 

direction of rotation selector and the direction of feed 
collar as described later in the 

Feed and Rotation Chart

.

WARNING:

Be careful when adjusting the feed direction selector 
collar, keep fingers and cord away from pinch points. 
Failure to heed this warning could result in fingers being 
pinched or the cord being damaged.

Summary of Contents for P4002

Page 1: ...ty Warnings 2 3 Drain Auger Safety Warnings 4 Electrical 5 Symbols 6 7 Features 8 Assembly 8 Operation 8 12 Maintenance 12 Illustrations 13 14 Parts Ordering and Service Back page INCLUT D gorgeoir po...

Page 2: ...his product only with batteries and chargers listed in tool appliance battery pack charger correlation supplement 987000 432 PERSONAL SAFETY Stay alert watch what you are doing and use common sense wh...

Page 3: ...dles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations BATTERY TOOL USE AND CARE Recharge only with the charger specified by the manufacturer A char...

Page 4: ...of possible hazards when not using your battery tool or when changing accessories Following this rule will reduce the risk of electric shock fire or serious personal injury Do not place battery tools...

Page 5: ...y that is 120 volts AC only normal household current 60 Hz Do not operate this product on direct current DC through the power cord A substantial voltage drop will cause a loss of power and the motor w...

Page 6: ...ng drawn into rotating drum Loose Clothing Risk of loose clothing being drawn into rotating drum Recycle Symbol This product uses lithium ion Li ion batteries Local state or federal laws may prohibit...

Page 7: ...ation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second W Watt Power mi...

Page 8: ...or unplugging power cord will prevent accidental starting that could cause serious personal injury WARNING Always wear eye protection with side shields marked to comply with ANSI Z87 1 Failure to do s...

Page 9: ...g or removing the battery pack when connecting or disconnecting the power cord and when manually advancing or retracting the cable Failure to follow these instructions could result in serious personal...

Page 10: ...d in and in the neutral N position Doing so will cause the cable to kink To retract the cable pull the feed direction selector collar out hold the front handle with one hand and pull the cable back wi...

Page 11: ...P trap If the cable is caught in a P trap additional force or increased trigger pressure should be enough to advance it past the bend in the pipe If the cable has contacted an obstruction there are t...

Page 12: ...could create a hazard or cause product damage WARNING To avoid serious personal injury always remove the battery pack or power cord from the tool when cleaning performing any maintenance or when stori...

Page 13: ...NOTES...

Page 14: ...duit le risque de d charge lectrique Utiliser ce produit seulement avec la piles et le chargeurs indiqu s dans le suppl ment de raccordement pour chargeur outils piles appareil n 987000 432 S CURIT PE...

Page 15: ...aires de l outil dans des circonstances impr vues UTILISATION ET ENTRETIEN DE LA PILE Ne recharger qu avec l appareil sp cifi par le fabricant Un chargeur appropri pour un type de pile peut cr er un r...

Page 16: ...e r duira les risques d incendie de choc lectrique et de blessures graves Ne pas placer les outils lectriques sans fil ou leurs piles proximit de flammes ou d une source de chaleur Ceci r duira les ri...

Page 17: ...iquement sur une alimentation 120 V c a courant r sidentiel standard 60 Hz Ne pas l utiliser sur une source de courant continu c c en le reliant par le cordon d alimentation Une chute de tension impor...

Page 18: ...symboles permettra d utiliser produit plus efficacement et de r duire les risques SYMBOLE NOM D SIGNATION EXPLICATION Symbole d alerte de s curit Indique un risque de blessure potentiel Lire manuel d...

Page 19: ...e de ces symboles permettra d utiliser produit plus efficacement et de r duire les risques SYMBOLE NOM D SIGNATION EXPLICATION V Volts Tension A Amp res Intensit Hz Hertz Fr quence cycles par seconde...

Page 20: ...l outil n est pas utilis Le fait de retirer la batterie permet d emp cher un d marrage accidentel pouvant entra ner des blessures graves AVERTISSEMENT Toujours porter une protection oculaire munie d c...

Page 21: ...es vitesses plus lev es si une pression accrue est exerc e et des vitesses moins lev es dans le cas d une pression r duite Pour mettre l outil EN MARCHE appuyer sur la g chette Pour TEINDRE l outil re...

Page 22: ...ble se trouve dans le tuyau de drainage Pour faire sortir ou r tracter le c ble en utilisant la g chette de commutateur Raccorder l outil une source d nergie CA ou CC Positionner le s lecteur de sens...

Page 23: ...en utilisant l interrupteur g chette ou continuer de faire sortir manuellement le c ble Le c ble doit progresser librement dans le tuyau de drainage jusqu ce qu il touche l obstruction ou se coince d...

Page 24: ...e l outil avant de le nettoyer de l entretenir ou de le ranger ENTRETIEN G N RAL viter d utiliser des solvants pour le nettoyage des pi ces en plastique La plupart des mati res plastiques peuvent tre...

Page 25: ...NOTES...

Page 26: ...perar una herramienta en lugares h medos use un suministro protegido por un interruptor de circuito con p rdida a tierra GFCI El uso de un GFCI reduce el riesgo de descargas el ctricas Usar este produ...

Page 27: ...la herramienta el ctrica para operaciones diferentes de las indicadas podr a originar una situaci n peligrosa Mantenga los mangos y superficies de agarre limpias y libres de aceite y grasa Los mangos...

Page 28: ...cuando est cambiando los accesorios de la misma Con el cumplimiento de esta regla se reduce el riesgo de una descarga el ctrica incendio o lesi n corporal seria No coloque herramientas de bater as ni...

Page 29: ...a uso dom stico 60 Hz No opere este producto con corriente directa corr cont a trav s del cord n el ctrico Una ca da considerable de voltaje causa una p rdida de potencia y el recalentamiento del moto...

Page 30: ...trapado en el tambor Ropa holgada Riesgo de que la ropa suelta quede atrapada en el tambor giratorio S mbolodereciclado Esteproductoutilizabater asdeionesdelitio Li ion Esposiblequealgunas leyes munic...

Page 31: ...etaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N V Voltios Voltaje A Amperios Corriente Hz Hertz Frecuencia ciclos por se...

Page 32: ...vita arrancar accidentalmente la unidad lo cual puede causar lesiones serias ADVERTENCIA Siempre p ngase protecci n ocular con protecci n lateral con la marca de cumplimiento de la norma ANSI Z87 1 Si...

Page 33: ...e estas instrucciones podr a causar lesiones personales de gravedad GATILLO DEL INTERRUPTOR DE VELOCIDAD VARIABLE Vea la figura 4 p gina 14 Elgatillodevelocidadvariableproducemayorvelocidadcuanta mayo...

Page 34: ...cable se encuentre en la tuber a de drenaje Para introducir y retraer el cable por medio del gatillo del interruptor siga estos pasos Conecte el producto a una fuente de alimentaci n CA o CC Coloque...

Page 35: ...la obstrucci n o quede atrapado en una trampa tipo p Si el cable queda atrapado en una trampa tipo p la fuerza adicional o la presi n adicional aumentada del gatillo deber a ser suficiente para avanza...

Page 36: ...vitar lesiones personales graves siempre retire el paquete de bater as o el cable de alimentaci n de la her ramienta antes de limpiarla realizarle tareas de mantenimiento o guardarla MANTENIMIENTO GEN...

Page 37: ...ar selector de direcci n de alimentaci n C Cable c ble cable D Auger tip bout du furet punta de la barrena E Drum tambour tambor A Battery pack bloc piles paquete de bater as B Depress latches to remo...

Page 38: ...ollar pulled out collier tir collar tirado hacia fuera B Collar pushed in collier enfonc collar empujado hacia dentro Fig 6 Fig 5 Fig 4 A Feed direction selector collar collier de s lection du sens d...

Page 39: ...NOTES NOTAS...

Page 40: ...is required MODEL NUMBER _______________ SERIAL NUMBER ____________________________ Pour faire une demande de r parations ou obtenir des pi ces de rechange trouver un Centre de r parations agr pour ob...

Reviews: