background image

6

INDIRECT LENGTH MEASUREMENT

STORING MEASURED VALUES

DELETING MEMORY

INDIRECT MEASUREMENT: PYTHAGORAS 2 POINTS 

(Fig. 7-8)

INDIRECT MEASUREMENT: PYTHAGORAS 3 POINTS 

(Fig. 9)

After the measurements, the date is stored automatically. It can 

store 19 measurements.

User can press the memory storage read button (3) to recall 

measurements. 

Press add button ”+” or subtraction button ”-” to turn up and down.

To delete the memory contents, firstly indicate       by pressing the 

memory storage read button, and then press off and memory 

delete button.

Even if the measuring tool is switched off, the value in the memory 

is retained.

Long press the add button ”+” to select the measurement unit 

among m, ft, in, ft+/in.

The use of a tripod is particularly helpful for greater distances. The 

laser distance measure can be screwed onto a commercially 

available tripod using the 1/4” thread on the bottom side of the 

housing.

1. Mount the tool to the tripod.

2. Set the measuring reference to the thread.

3. Start to take measurements.

Pay attention that the reference point of the measurement (e.g., 

the rear edge of the measuring tool) is at the exact same location 

for both measurements.
After completing the second measurement, the height of the 

building is calculated automatically. The last individual measured 

value is indicated at the middle line in the display, while the final 

result is indicated at the top.

1. After switching on, press function button four times, the   

    appears on display.

2. Press measuring/on button to activate laser and aim at the point 

which is to be measured

3. Press measuring/on button again to take the first measurement, 

and again to take the second and third measurement.

4. The height of building, second and third distance value will be 

seen on display.

CONTINUOUS/TRACKING MEASUREMENT (Fig. 10-11)

For continuous/tracking measurements, the measuring tool can be 

moved relative to the target, whereby the measuring value is 

updated approx. every 0.4 seconds. In this manner, as an 

example, you can move a certain distance away from a wall, while 

the actual distance can always be read.

To start continuous measurements, push measuring/on button for 

a few second.
Continuous measurement automatically switches off after 100 

times measurements (about 30 seconds).

The last measured value remains indicated on the display. 

To stop continuous measurement, press off and memory delete 

button (7). Pres it one more time to exit and return to the single 

length measurement mode.

The indirect length measurement is used to measure distances 

that cannot be measured directly because an obstacle would 

obstruct the laser beam or no target surface is available as a 

reflector. Correct results are achieved only when the laser beam 

and the sought distance from an exact right angle (Pythagorean 

Theorem)

1. After switching on, press the function button three times, the

    symbol       appears.
2. Press measuring/on button to activate laser and aim at the point

    which is to be measured.
3. Press measuring/on button again to take the first measurement, 

    and again to take the second measurement.
4. The height of building (third side of triangle), first and second 

    distance value will be seen on display. 

MEMORY FUNCTION (Fig. 12)

MEASUREMENT UNIT SELECTION

Long press the reference point selection button to switch on or off 

the display backlight.

User can trigger the function when it is in dark situation. The value 

is clearly visible on the display.

DISPLAY BACKLIT

WORKING WITH TRIPOD (available separately)

WORKING ADVICE

The reception lens 12 and the laser beam outlet 11 must not be 

covered when taking a measurement.

The measuring tool must not be moved while taking a measure-

ment (with the exception of the continuous measurement function). 

Therefore, place the measuring tool, as far as this is possible, 

against or on the measuring points.

Measurement takes place at the centre of the laser beam, even 

when target surfaces are sighted at an incline.

The measuring range depends upon the light conditions and the 

reflection properties of the target surface. For improved visibility of 

the laser beam when working outdoors and when the sunlight is 

intense, use the laser viewing glasses (accessory) and the laser 

target plate (accessory), or shade off the target surface.

If required, use the laser target plate (accessory) on these 

surfaces.
Also, air layers with varying temperatures or indirectly received 

reflections can affect the measured value.

GENERAL INFORMATION

INFLUENCE EFFECTS ON THE MEASURING RANGE

Due to physical effects, faulty measurements cannot be excluded 

when measuring on different surfaces. Included here are:

• 

transparent surfaces (e.g., glass, water),

• 

reflecting surfaces (e.g., polished metal, glass),

• 

porous surfaces (e.g. insulation materials),

• 

structured surfaces (e.g., roughcast, natural stone).

INFLUENCE EFFECTS ON THE MEASURING RESULT

Summary of Contents for LDM-60

Page 1: ...LDM 60 ...

Page 2: ...1 9 10 12 11 a f g b c 1 2 4 6 3 5 8 e 7 ...

Page 3: ...2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Page 4: ...0 5 m 2 4 5 m 3 Fig 7 1 2 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 1 3 2 ...

Page 5: ... 8 Display 9 Latch of battery lid 10 Battery lid 11 Laser beam outlet 12 Reception lens a Variable measuring functions b Need to repair f Measurement reference level g Measured values stored c Battery indicator Measuring range typically 0 05 60m Measuring accuracy typically 2 0mm Operating temperature 10 C 40 C Laser class 2 Laser type 635 nm 1mW Batteries 2 x 1 5 V LR03 AAA Estimated battery life...

Page 6: ...e total distance after you measure the first distance press add button 4 then again press measuring on button to measure the distance you want to add it can calculate automatically and the result displayed 2 After switching on when you want to measure the short distance after you measure the first distance press subtraction button 5 then again press measuring on button to measure the distance you ...

Page 7: ...y To stop continuous measurement press off and memory delete button 7 Pres it one more time to exit and return to the single length measurement mode The indirect length measurement is used to measure distances that cannot be measured directly because an obstacle would obstruct the laser beam or no target surface is available as a reflector Correct results are achieved only when the laser beam and ...

Page 8: ...Do not disassemble the laser measuring tool this will expose the user to hazardous radiation exposure 9 Do not attempt to change any part of the laser lens ACCURACY CHECK OF THE MEASURING TOOL The accuracy of the measuring tool can be checked as follows Select a permanently unchangeable measuring section with a lengh of approx 3 to 10 metres its length must be precisely known e g the width of a ro...

Page 9: ... 8 NOTE ...

Page 10: ... 9 NOTE ...

Page 11: ... 10 NOTE ...

Page 12: ......

Reviews: