background image

2

INFORMATION ON MECHANICAL IMPACT(VIBRATION)

The characteristic vibration values for the fastener driving 
tool have been determined in accordance with ISO 8662-
11:1999 and EN 12096 – Measurement of vibration in 
hand-held power tools – Part 11: Fastener driving tools 

VHH6SHFL¿FDWLRQV

This value is a tool-related characteristic value and does 

QRWUHSUHVHQWWKHLQÀXHQFHWRWKHKDQGDUPV\VWHPZKHQ
XVLQJWKHWRRO$QLQÀXHQFHWRWKHKDQGDUPV\VWHPZKHQ

using the tool will for example depend on the gripping 
force, the contact pressure force, the working direction, 
the adjustment of compressed air supply, the workplace 
and the work piece support.

ADDITIONAL SAFETY INSTRUCTIONS FOR 
PNEUMATIC POWER TOOLS

 

Ŷ

Air under pressure can cause severe injury.

 

Ŷ

Always shut off air supply, drain hose of air pressure 
and disconnect tool from air supply whenever not in 
use, before changing accessories or where making 
repairs.

 

Ŷ

Never direct air at yourself or anyone else.

 

Ŷ

Whipping hoses can cause severe injury. Always 
check for damaged or loose hoses and fittings.

 

Ŷ

Cold air should be directed away from the hands.

 

Ŷ :KHQHYHU XQLYHUVDO WZLVW FRXSOLQJV FODZ FRXSOLQJV

are used, lock pins shall be installed and whip check 
safety cables shall be used to safeguard against 
possible hose-to-tool and hose-to-hose connection 
failure.

 

Ŷ

Do not exceed the maximum air pressure stated on 
the tool.

 

Ŷ

Never carry an air tool by the hose.

 

Ŷ

Only fasteners listed in the specifications may be used 
in the fastener driving tool. The fastener driving tool 
and the fasteners specified in the specifications are to 
be considered as one unit safety system.

 

Ŷ

Quick action couplings shall be used for connection 
to the compressed air system and the non-sealable 
nipple must be fitted at the tool in such a way that no 
compressed air remains in the tool after disconnection.

 

Ŷ

Oxygen or combustible gases shall not be used as an 
energy source for compressed air operated fastener 
driving tools.

 

Ŷ

Fastener driving tools shall only be connected to an 
air supply where the maximum allowable pressure of 
the tool cannot be exceeded by more than 10%; in the 
case of higher pressure ,a pressure reducing valve 
which includes a downstream safety valve shall be 
built into the compressed air supply.

 

Ŷ

Only the main energy and the lubricants listed in 
the operating instructions may be used for the 
maintenance of fastener driving tools. Only spare 
parts specified by the manufacturer or his authorised 
representative shall be used.

 

Ŷ

Repairs shall be carried out only by the manufacturer's 
authorized agents or by other experts, having due 
regard to the information given in the operating 
instructions.

 

Ŷ

Stands for mounting the fastener driving tools to a 
support, for example to a work table, shall be designed 
and constructed by the stand manufacturer in such 
a way that the fastener driving tools can be safely 
fixed for the intended use, thus for example avoiding 
damage, distortion and displacement.

 

Ŷ

Check prior to each operation that the safety and 
triggering mechanism is functioning properly and that 
all nuts and bolts are right.

 

Ŷ

Do not carry out any alterations to the fastener driving 
tool.

 

Ŷ

Do not disassemble or make inoperative any parts of 
the fastener driving tool such as the safety yoke.

 

Ŷ

Do not perform any “emergency repairs” without 
proper tools and equipment.

 

Ŷ

The fastener driving tool should be serviced properly 
and at regular intervals in accordance with the 
manufacturer’s instructions.

 

Ŷ

Avoid weakening or damaging the tool, for example 
by:

 

– punching or engraving;

 

– modification not authorized by the manufacturer;

 

– guiding against templates made of hard material 

such as steel;

 

– dropping or pushing across the floor;

 

– using the tool as a hammer;

 

– applying excessive force of any kind.

 

Ŷ

Never point any fastener driving tool at yourself or at 
any other person or animal.

 

Ŷ

Hold the fastener driving tool during the work operation 
in such a way that no injuries can be caused to the 
head or to the body in the event of possible recoil 
consequent upon a disruption in the compressed air 
supply or hard areas within the workplace.

 

Ŷ

Never actuate the fastener driving tool into free space. 
This will avoid any hazard caused by free flying 
fasteners and excessive strain of the tool.

 

Ŷ

The tool shall be disconnected from the compressed 
air system for the purpose of transportation, especially 
where ladders are used or where an unusual physical 
posture is adopted whilst moving .

 

Ŷ

Carry the fastener driving tool at the workplace using 
only the handle, and never with the trigger actuated.

 

Ŷ

Take conditions at the workplace into account. 
Fasteners can penetrate thin work pieces or slip off 
corners and edges of workplaces, and thus put people 
at risk.

 

Ŷ

For personal safety, use protective equipment such ad 
hearing and eye protection.

 

Ŷ

Fastener driving tools are operated by actuating the 

Summary of Contents for 6210565

Page 1: ...6GA C BRAD NAILER OPERATOR S MANUAL ORIGINAL INSTRUCTIONS RA NB1664 S Important It is essential you read the instructions in this manual before starting and operating this machine 6XEMHFW WR WHFKQLFDO...

Page 2: ...ig 6 1 2 2 1 3 1 1 5 8 6 7 7 6 3 2 4 8 DESCRIPTION 1 NITTO style coupler 2 No mar pad 3 Safety yoke 4 Exhaust cap 5 Air supply 6 Nails 7 Pusher 8 Magazine 9 Depth adjustment knob 10 Trigger 11 Jam rel...

Page 3: ...1 2 Fig 7 Fig 9 Fig 8 Fig 10 6 7 10 11 12 8 9 Fig 11 Quick connector Quick connector Lubricator Filter Cut off valve Regulator 0 8 5 bar Quick coupler Tool Air compressor Quick coupler Air hose...

Page 4: ...ol the operator should adopt a comfortable posture while maintaining a secure footing and avoiding awkward or off balanced postures The operator should change posture during extended tasks which can h...

Page 5: ...ructions may be used for the maintenance of fastener driving tools Only spare parts specified by the manufacturer or his authorised representative shall be used Repairs shall be carried out only by th...

Page 6: ...should have an internal diameter of at least 19 mm and a corresponding large diameter where relatively long pipelines or multiple users are involved Compressed air pipelines should be laid so as to fo...

Page 7: ...ARNING Ensure the air supply is clean and does not exceed EDU SVL ZKLOH RSHUDWLQJ WKH SURGXFW 7RR high an air pressure and unclean air will shorten the product s life due to excessive wear and may be...

Page 8: ...r twice a day with heavy use Only a few drops of oil at a time is necessary Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle Before connecting the tool check...

Page 9: ...session before connecting to an air supply 1 Connect the tool to the air supply 2 Slide the pusher all the way to the rear of the magazine 3 With the safety yoke of the tool pointed away from you feed...

Page 10: ...ust the depth adjustment knob to reach the good fastening effect Work with the lowest possible air pressure This will give RX WKUHH VLJQL FDQW DGYDQWDJHV 1 Energy will be saved 2 Less noise will be pr...

Page 11: ...freezing the moisture in the air line may freeze and prevent tool operation We recommend the use of air tool lubricant or SHUPDQHQW DQWLIUHH H HWK OHQH JO FRO DV D FROG ZHDWKHU lubricant WARNING Do n...

Page 12: ...s without fasteners loaded The lubricator is properly set when a light stain of oil collects on the paper Excessive amounts of oil should be avoided If it becomes necessary to store the product for an...

Page 13: ...damaged O rings or seals Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Verify adequate air supply Inadequate lubrication Lubricate tool Worn or damaged O rings or...

Page 14: ...75 Pin 4 x 16 10 O ring 48 7 x 2 65 32 Guide sleeve 54 Pin bush 76 Trigger 11 O ring 38 x 3 5 33 Bolt M4 x 7 55 Split washer 2 5 77 Safety screen 12 O ring 25 x 3 5 34 Adjusting nut 56 Pin 78 Pin 2 5...

Page 15: ...NITTO is a registered trademark owned by Nitto Kohki Co Ltd...

Page 16: ...tralia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Australia Techtronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand 5 2 LV D WUDGHPDUN RI 5 REL LPLWHG...

Reviews: