[User Guide AutoSealer 1001]
[Rx Systems, Inc.]
Page 5
5 Operating Instructions
The AutoSealer will automatically seal pill cards at a constant temperature and pressure
over a set time – you only need to push two buttons to start the sealing cycle. But before
you do, there are some one-time adjustments you need to make.
1.
Remove the AutoSealer from its packing. Save all packaging materials for future use
– in the unlikely event that we need to repair the machine at our facilities.
Replacement packaging is expensive and required for shipping.
2.
Plug the AutoSealer into a standard 3-prong outlet. It is recommended to use a
dedicated 20amp outlet.
3.
Turn the power switch to “ON” – the red switch light will illuminate.
4.
Temperature: Your AutoSealer is pre-set to heat to 315 degrees. Should you need to
adjust this setting (note card type and respective temperature requirement):
a.
Push and hold blue
set
button below digital readout.
b.
While set button is pushed in – push the gray
up
arrow to increase
temperature setting or gray
down
arrow to decrease.
c.
When the digital meter reaches your desired setting release both buttons.
d.
Your AutoSealer temperature is set.
NOTE:
D
O NOT EXCEED THE TEMPERATURE REQUIREMENT FOR YOUR
CARD
–
THIS WILL POTENTIALLY DAMAGE THE CARD
.
CARD
TYPE
TEMPERATURE
TIME
Uni-Series (6” x 9”)
Temperature
should
be set at
315 degrees
For all Rx Systems
Pill cards.
3 seconds
M-Series (6” x 9”)
3 seconds
Rx Series (6.375’ x 9”)
5 seconds
UD Blister & Foil
1 second
UD Card
2 seconds
MD-Series*
3 seconds