RWC PLANAR 230 Manual Download Page 2

GENERAL FUNCTION

Please read these instructions carefully and ensure that the mixing valve is 
installed to Local Authority Regulations.

The Planar™ 230 and 330 thermostatic mixing valves are suitable for use 
on low pressure hot and cold water supplies down to a minimum of 0.2 
bar dynamic pressure (2 metre head) when used with the appropriate low 
pressure shower heads. For best performance the recommended dynamic 
pressure range is 0.5 - 2.0 bar (5 metre- 20 metre head) with a pressure 
loss ratio of no more than 2:1. The thermostatic shower is factory preset 
to 41°C ± 3°C with a balanced flow pressure of 2 bar. If the maximum tem-
perature setting is affected due to special installation conditions, the ther-
mostat can be adjusted on site to compensate.

WORKING PARAMETERS AND SPECIFICATIONS

 

 

 

 

Planar™230    

Planar™330

Minimum flow pressure:  

0.2 bar   

 

0.2 bar

Test pressure static:  

 

16.0 bar  

 

16.0 bar

Working pressure dynamic:  

3.5 bar max.  

 

3.5 bar max.

Maximum pressure loss ratio:   2:1  

 

 

2:1

Maximum hot water 
temperature at the inlet:  

85°C    

 

85°C

Recommended stored 
temperature:    

 

60°C    

 

60°C

Minimum hot/blend 
temperature difference to 
ensure shut-off on cold 
supply failure:    

 

15°C    

 

15°C

Factory setting at 2 bar 
equal pressures:  

 

41°C ± 3°C  

 

41°C ± 3°C

Minimum flow rate  

 

8 LPM    

 

10 LPM

Flow delivery at 40°C mixed  

 

 

 

 

 

water temperature at 1  

 

 

 

 

 

 

bar pressure loss:  

 

75 LPM  

 

110 LPM

At flow pressures of over 3.5 bar, or when the differential is >2:1, it is
recommended that a Syr pressure reducing valve be fitted in the supply 
line(s).

low rate

NOTES