![RVP 6536 SERIES Service Manual Download Page 29](http://html1.mh-extra.com/html/rvp/6536-series/6536-series_service-manual_1503350029.webp)
29
Outdoor Blower System #2
Red L.E.D. 3
High Speed (See Figure 13)
N
O
Line Volts 115 VAC To Terminal
T8 & T9 On P.C. Board. L1 Line
Power From Compressor #2 Relay.
Refer To Compressor #2
Checkout
NO
O
K
115 VAC To T12 & T13 On
P.C. Board
Replace P.C. Board
NO
O
K
Check Wiring To O.D. Blower.
Check Capacitor. Check Motor
For Open Or Ground.
Rewire To Motor Or Replace
Components As Necessary.
CHECKOUT OUTDOOR BLOWER
HIGH SPEED
HEATING AND COOLING MODES