![RVP 6536 SERIES Service Manual Download Page 25](http://html1.mh-extra.com/html/rvp/6536-series/6536-series_service-manual_1503350025.webp)
25
115 VAC To System #1
T1 & T5 On P.C. Board
Restore Power
12 VDC To GH&B
At Thermostat
Check 12 VDC To
R&B At Thermostat
Restore 12 VDC
R (+) B (-)
Replace Thermostat
12 VDC To Pin Connectors
GH&B On P.C. Board
(See Figure 14)
Check All Pin Connectors And
Connection From Thermostat.
Replace Lifeline If Necessary.
115 VAC To N.O. Contact
On Relay #4 And T5 On
P.C. Board (See Figure 13)
NO
O
K
NO
NO
O
K
NO
O
K
O
K
NO
Replace P.C. Board
O
K
Check Wiring To Motor. Check
Capacitor And Motor Windings
For Open Or Ground.
Reconnect Wiring Or
Replace Capacitor Or
Motor If Necessary
NO
I.D. BLOWER HIGH SPEED
THERMOSTAT ON HIGH FAN
COOL ONLY
Note: All operating functions subject to thermostat time delays.
Summary of Contents for 6536 SERIES
Page 1: ...SERVICE MANUAL FOR 6536 SERIES PACKAGED HEAT PUMPS...
Page 4: ...4 4 UNIT SPECIFICATIONS AND IDENTIFICATION...
Page 18: ...18 17 WIRING DIAGRAM 6536 Series Packaged Heat Pump 2 Compressor...
Page 19: ...19 18 WIREBOX COMPONENT CHECKOUT...
Page 28: ...28 CHECKOUT OUTDOOR BLOWER LOW SPEED HEATING AND COOLING MODES...
Page 36: ...RV Products A Division of Airxcel Inc P O Box 4020 Wichita KS 67204 1976A281 1 00 PP...