background image

11

 

Routing of the thermostat wiring harness must comply with

all local and national electrical codes.  Collect any excess
thermostat harness in the air conditioner mounting
compartment.  Be sure to secure the excess wiring within the
compartment.  Coiling the excess harness into 3" diameter
circles or larger is acceptable.

THERMOSTAT MOUNTING

Follow the instructions packed with the thermostat to select a
location for thermostat mounting.  Pay particular attention to
choose a location which is not totally isolated from air
currents and is not subject to direct discharge from an air
register.

11.  CHECKOUT

1.

Before engaging power to any system, insure the
following:

A)

All tools have been removed from the
equipment.

B)

All wiring is attached, routed and properly
secured.

C)

All panels (both mechanical and electrical)
are in place.

D)

The thermostat system switch is placed into
the “OFF” position and fan switch is placed
in the “Auto” position.

E)

All co-workers have been warned that the
equipment is being energized.

2.

System wiring may be checked by referring to the
wiring diagram located on the back of the wiring box
door. 

3.

Before beginning the checkout procedure, thoroughly
read the instructions in either the thermostat
installation instructions or in the owners manual
provided with this product.

Keep in mind that the wall thermostat provides a 
3 minute delay between off and on cycles. 

There is also a 30 second delay between 1

st

 and 2

nd

 

stage cooling.  This is to prevent both compressors
from starting simultaneously.  To insure that the
thermostat calls for both 1

st

 and 2

nd

 stage cooling,

verify that the cool setpoint is well below actual
indoor temperature.

4.

After complying with steps 1 through 3, engage
power to all systems and begin checkout procedure.

5.

Test each thermostat function such as fan modes and
cool modes to insure proper operation.

Summary of Contents for 6636 Series

Page 1: ...INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER...

Page 2: ...3 3 Unit Identification 3 4 Unit Depiction Figures 4 5 General Information 5 6 Unit Installation 5 7 Duct Mounting and Configuration 6 8 Duct and Register Specifications 7 9 115 VAC Electrical Wiring...

Page 3: ...REFULLY FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THIS BOOKLET TO AVOID DAMAGE TO THE EQUIPMENT PERSONAL INJURY OR FIRE WARNING Improper installation may damage equipment can create a hazard and will vo...

Page 4: ...4 4 DEPICTION FIGURES...

Page 5: ...ce through the discharge opening Figures 1 and 2 show the location of both the air conditioner s condensing coil and discharge air opening The air conditioner must be installed so that the side that h...

Page 6: ...NG AND CONFIGURATION This system is designed for the back of the air conditioner to seal to the vehicle The ducting for the air conditioner attaches and seals to the side Cut outs in the flooring prov...

Page 7: ...d to heat sources must be further insulated to prevent significant performance degradation due to heat gain An example of an area capable of creating significant heat gain is the roof area which can s...

Page 8: ...o the BLACK high voltage lug 2 Connect each circuits white 0 V to GND power lead to the WHITE high voltage lug 3 Connect each circuits green or bare copper ground wire to the grounding lugs located in...

Page 9: ...ing insulation E After connecting the ground wire to the grounding lug verify that the ground wire which in some instances will be bare copper cannot come into contact with any high voltage terminal 6...

Page 10: ...and pins for this connection must be purchased separately Both the receptacle and the pins are manufactured by AMP Aircraft Marine Products Inc Harrisburg PA In most cases the parts can be obtained th...

Page 11: ...The thermostat system switch is placed into the OFF position and fan switch is placed in the Auto position E All co workers have been warned that the equipment is being energized 2 System wiring may...

Page 12: ...RV Products A Division of Airxcel Inc P O Box 4020 Wichita KS 67204 1976L118 7 04 PP...