![Ruud UPRL- JEZ Manual Download Page 9](http://html1.mh-extra.com/html/ruud/uprl-jez/uprl-jez_manual_1503207009.webp)
Ruud Heating, Cooling and Water Heating
9
Outdoor
Unit
UPRL-
Model Numbers
Stage
ARI Cooling Performance
80°
[26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
ARI Heating Performance (70°F [21°C] Indoor)
ID Coil
SEER
Total
Capacity
BTU/H [kW]
COP
BTU/H [kW]
COP
ID Air Mover
BTU/H [kW]
BTU/H [kW]
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
Outdoor Air
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
47°F [8.5°C] DB/
43°F [6°C] WB
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
DOE
Region IV
HSPF
ARI Ratings
Net Latent
BTU/H [kW]
Net Sensible
BTU/H [kW]
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
EER
048JEZ
RCFM-H*4824A*
UGFD-09?ZCM?
1
26,300
[7.7]
8,700 [2.5]
46,000 [13.5]
14.50
11.20
1150 [543]
71
33,600 [9.8]
3.96
18,900 [5.5]
2.42
45,500 [13.3]
27,000 [7.9]
9.00
2
34,500 [10.1]
11,500 [3.4]
1600 [755]
72
45,500 [13.3]
27,000 [7.9]
UGFD-10?ZCM?
1
26,250 [7.7]
8,550 [2.5]
46,000 [13.5]
14.00
10.90
1175 [554]
71
33,600 [9.8]
3.88
19,000 [5.6]
2.38
45,500 [13.3]
27,400 [8.0]
9.00
2
34,250 [10.0]
11,750 [3.4]
1625 [767]
72
45,500 [13.3]
27,400 [8.0]
UGFD-12?RCM?
1
26,250 [7.7]
8,550 [2.5]
46,500 [13.6]
14.50
11.45
1225 [578]
71
33,600 [9.8]
4.00
18,900 [5.5]
2.44
45,000 [13.2]
27,000 [7.9]
9.00
2
34,650 [10.2]
11,850 [3.5]
1650 [779]
72
45,000 [13.2]
27,000 [7.9]
UGGD-09?ZCM?
1
26,300 [7.7]
8,700 [2.5]
46,000 [13.5]
14.50
11.00
1175 [554]
71
33,600
[9.8]
3.88
18,900 [5.5]
2.38
45,500 [13.3]
27,400 [8.0]
9.00
2
34,450 [10.1]
11,550 [3.4]
1675 [790]
72
45,500 [13.3]
27,400 [8.0]
UGGD-10?ZCM?
1
26,300
[7.7]
8,700 [2.5]
46,000 [13.5]
14.50
11.05
1175 [554]
71
33,600 [9.8]
3.92
18,900 [5.5]
2.40
45,500 [13.3]
27,200 [8.0]
9.00
2
34,350 [10.1]
11,650 [3.4]
1625 [767]
72
45,500 [13.3]
27,200 [8.0]
UGGD-12?RCM?
1
26,350 [7.7]
8,650 [2.5]
46,000 [13.5]
14.50
11.25
1225 [578]
71
33,600
[9.8]
3.96
18,800 [5.5]
2.42
45,500 [13.3]
27,000 [7.9]
9.00
2
34,500 [10.1]
11,500 [3.4]
1650 [779]
72
45,500 [13.3]
27,000 [7.9]
UGJD-09?ZCM?
1
26,300 [7.7]
8,700 [2.5]
46,000 [13.5]
14.50
11.00
1175 [554]
71
33,600 [9.8]
3.88
18,900 [5.5]
2.38
45,500 [13.3]
27,400 [8.0]
9.00
2
34,450 [10.1]
11,550 [3.4]
1675 [790]
72
45,500 [13.3]
27,400 [8.0]
UGJD-10?ZCM?
1
26,300 [7.7]
8,700 [2.5]
46,000 [13.5]
14.50
11.05
1175 [554]
71
33,600 [9.8]
3.92
18,900 [5.5]
2.40
45,500 [13.3]
27,200 [8.0]
9.00
2
34,350 [10.1]
11,650 [3.4]
1625 [767]
72
45,500 [13.3]
27,200 [8.0]
UGJD-12?RCM?
1
26,350 [7.7]
8,650 [2.5]
46,000 [13.5]
14.50
11.25
1225 [578]
71
33,600 [9.8]
3.96
18,800 [5.5]
2.42
45,500 [13.3]
27,000 [7.9]
9.00
2
34,500 [10.1]
11,500 [3.4]
1650 [779]
72
45,500 [13.3]
27,000 [7.9]
UGLR-10?BRM?
1
26,400 [7.7]
8,600 [2.5]
46,500 [13.6]
14.50
11.55
1200 [566]
71
33,400
[9.8]
4.06
18,800 [5.5]
2.46
45,000 [13.2]
26,800 [7.9]
9.00
2
34,550 [10.1]
11,950 [3.5]
1575 [743]
72
45,000 [13.2]
26,800 [7.9]
UGLR-12?ARM?
1
26,400 [7.7]
8,600 [2.5]
46,500 [13.6]
14.50
11.65
1200 [566]
71
33,400 [9.8]
4.06
18,800 [5.5]
2.48
45,000 [13.2]
26,600 [7.8]
9.00
2
34,800 [10.2]
11,700 [3.4]
1600 [755]
72
45,000 [13.2]
26,600 [7.8]
UGPR-07?BRQ?
1
26,400 [7.7]
8,600 [2.5]
46,500 [13.6]
14.50
11.60
1225 [578]
71
33,400 [9.8]
4.06
18,800 [5.5]
2.46
45,000 [13.2]
26,800 [7.9]
9.00
2
34,750 [10.2]
11,750 [3.4]
1625 [767]
72
45,000 [13.2]
26,800 [7.9]
UGPR-10?BRM?
1
26,300 [7.7]
8,700 [2.5]
46,500 [13.6]
14.50
11.35
1200 [566]
71
33,600 [9.8]
4.00
18,800 [5.5]
2.44
45,000 [13.2]
27,000 [7.9]
9.00
2
34,600 [10.1]
11,900 [3.5]
1625 [767]
72
45,000 [13.2]
27,000 [7.9]
UGPR-12?ARM?
1
26,350 [7.7]
8,650 [2.5]
46,500 [13.6]
14.50
11.65
1250 [590]
71
33,400 [9.8]
4.06
18,800 [5.5]
2.48
45,000 [13.2]
26,600 [7.8]
9.00
2
34,600 [10.1]
11,900 [3.5]
1575 [743]
72
45,000 [13.2]
26,600 [7.8]
RCFM-H*4824A*+RXMD-C06
Coil Only
1
25,050
[7.3]
8,750 [2.6]
45,500 [13.3]
13.50
11.45
1200 [566]
71
34,200 [10.0]
3.98
19,500 [5.7]
2.44
44,500 [13.0]
26,600 [7.8]
8.50
2
33,800
[9.9]
11,700 [3.4]
1475 [696]
72
44,500 [13.0]
26,600 [7.8]
Rev
.
3/28/2008
P
erf
ormance Data ARI Standar
d Conditions
(con’t.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
[
] Designates Metric Con
ver