![Ruud UPRL- JEZ Manual Download Page 6](http://html1.mh-extra.com/html/ruud/uprl-jez/uprl-jez_manual_1503207006.webp)
6
Ruud Heating, Cooling and Water Heating
Outdoor
Unit
UPRL-
Model Numbers
Stage
ARI Cooling Performance
80°
[26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
ARI Heating Performance (70°F [21°C] Indoor)
036JEZ
RCSM-H*3621A*
➀
1
19,350 [5.7]
6,450 [1.9]
16.50
35,400 [10.4]
12.75
71
24,000 [7.0]
3.68
14,900 [4.4]
2.38
875 [413]
UHPL-HM3621
33,400
[9.8]
21,400 [6.3]
8.70
ID Coil
SEER
Total
Capacity
BTU/H [kW]
COP
BTU/H [kW]
COP
ID Air Mover
BTU/H [kW]
BTU/H [kW]
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
Outdoor Air
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
47°F [8.5°C] DB/
43°F [6°C] WB
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
DOE
Region IV
HSPF
ARI Ratings
Net Latent
BTU/H [kW]
Net Sensible
BTU/H [kW]
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
EER
2
25,700 [7.5]
9,700 [2.8]
72
33,400 [9.8]
21,400 [6.3]
1200 [566]
Rev
.
3/28/2008
1 - dehumid
16,050 [4.7]
2,650 [0.8]
750 [354]
71
2 - dehumid
23,000 [6.7]
6,800 [2.0]
950 [448]
72
RCFM-H*3617A*
UGFD-06?MCK?
1
19,000 [5.6]
6,400 [1.9]
34,600 [10.1]
15.00
11.50
875 [413]
71
24,400 [7.1]
3.48
15,300 [4.5]
2.38
34,000 [10.0]
22,200 [6.5]
8.25
2
25,100 [7.4]
9,500 [2.8]
1175 [554]
72
34,000 [10.0]
22,200 [6.5]
UGFD-07?MCK?
1
19,050 [5.6]
6,350 [1.9]
34,400 [10.1]
15.00
11.40
900 [425]
71
24,400 [7.1]
3.46
15,200 [4.5]
2.38
34,200 [10.0]
22,200 [6.5]
8.70
2
25,050 [7.3]
9,350 [2.7]
1200 [566]
72
34,200 [10.0]
22,200 [6.5]
UGGD-06?MCK?
1
19,100 [5.6]
6,300 [1.8]
34,600 [10.1]
15.50
11.55
900 [425]
71
24,200 [7.1]
3.50
15,100 [4.4]
2.40
34,000 [10.0]
22,000 [6.4]
8.70
2
25,150 [7.4]
9,450 [2.8]
1225 [578]
72
34,000 [10.0]
22,000 [6.4]
UGGD-07?MCK?
1
19,050 [5.6]
6,350 [1.9]
34,600 [10.1]
15.00
11.45
925 [437]
71
24,200 [7.1]
3.48
15,200 [4.5]
2.38
34,000 [10.0]
22,200 [6.5]
8.70
2
25,050 [7.3]
9,550 [2.8]
1225 [578]
72
34,000 [10.0]
22,200 [6.5]
UGJD-06?MCK?
1
19,100 [5.6]
6,300 [1.8]
34,600 [10.1]
15.50
11.55
900 [425]
71
24,200 [7.1]
3.50
15,100 [4.4]
2.40
34,000 [10.0]
22,000 [6.4]
8.70
2
25,150 [7.4]
9,450 [2.8]
1225 [578]
72
34,000 [10.0]
22,000 [6.4]
UGJD-07?MCK?
1
19,050 [5.6]
6,350 [1.9]
34,600 [10.1]
15.00
11.45
925 [437]
71
24,200 [7.1]
3.48
15,200 [4.5]
2.38
34,000 [10.0]
22,200 [6.5]
8.70
2
25,050 [7.3]
9,550 [2.8]
1225 [578]
72
34,000 [10.0]
22,200 [6.5]
UGLR-07?AMK?
1
19,200 [5.6]
6,400 [1.9]
35,000 [10.3]
16.00
12.00
925 [437]
71
24,200 [7.1]
3.58
15,000 [4.4]
2.44
33,800
[9.9]
21,800 [6.4]
8.70
2
25,350 [7.4]
9,650 [2.8]
1200 [566]
72
33,800 [9.9]
21,800 [6.4]
UGPR-05?BMK?
1
19,000 [5.6]
6,400 [1.9]
34,600 [10.1]
15.00
11.50
900 [425]
71
24,400 [7.1]
3.48
15,300 [4.5]
2.38
34,000 [10.0]
22,000 [6.4]
8.25
2
25,100 [7.4]
9,500 [2.8]
1200 [566]
72
34,000 [10.0]
22,000 [6.4]
RCFM-H*3617A*+RXMD-C06
Coil Only
1
18,150 [5.3]
6,450 [1.9]
34,200 [10.0]
14.00
11.85
875 [413]
71
24,800 [7.3]
3.52
15,600 [4.6]
2.40
33,200
[9.7]
21,600 [6.3]
8.25
2
24,700 [7.2]
9,500 [2.8]
1070 [505]
72
33,200 [9.7]
21,600 [6.3]
P
erf
ormance Data ARI Standar
d Conditions
(con’t.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
➀
Highest sales volume tested combination required by DOE test procedures.
[
] Designates Metric Con
ver
sions