Setting
Adjustment range
Backlight
0 – 29
ID Type
Real, At 6kHz, At 12 kHz, R -90 +90, 6 -90 +90, 12 -90 +90
Hold Time
1 – 10
ID Gain
Normal, High
Language
Polski, English, Deutsch, Cestina, Lietuvių, Latviešu, Türk, Français *
*
The manufacturer reserves the right to add additional menu languages without notice
The
Screen
page contains the following settings:
Backlight
Adjustment of the display’s backlight. This allows searching in low light conditions. If the
backlight setting is 0, then when entering the menu the backlight will automatically switch on.
The backlight will switch off by leaving the menu screen.
ID Type
Identification of the type of object depending on the frequency. As the operation
frequency of the detector changes, the ID value of non-ferrous objects increases and the ID
value of ferrous objects is subjected to much more complex rules. It is difficult to memorize the
IDs of different objects if the user has a total of 71 frequencies to choose from. This is the
reason the detector has the ability to calculate the IDs to standard values for two frequencies:
6 kHz and 12 kHz or to present the Real ID.
While searching for small objects on high frequencies we suggest using the function of
calculating the ID for 12 kHz – this way it is easy to recognize small differences in ID values
between a foil and the desired objects. In other cases we suggest using the function of
calculating the ID for 6 kHz. The use of the Real ID function is advised only for experienced
users.
The ID Type setting has 6 items. The first three positions cause the detector to work with
the identification in the range of 1 - 120, the next three switch the detector to the identification
system in the range -90 +90.
Hold Time
This function allows adjustment to the time that the screen shows information. In clear
terrain we suggest using the high values, for littered areas the lower ones are recommended.
ID Gain
The function allows the sensitivity of the identification system to be increased. In this way,
even the weakest signals are shown in digits and on the identification graph on the display.
However, the user should be aware that the interpretation of graph and identification values for
the weakest signals is difficult and requires a lot of experience.
Language
Allows the menu language to be chosen.
RUTUS
Alter71
ver. 2.0
17