Rutenbeck Control IP 4 Operating Instructions Manual Download Page 9

 Settings 9

Increase the access security 

to the Control IP 4 by setting 

an individual user name and 

a password in the “Settings” 

menu. (Fig. 2, G).

As soon as you issue a pass-

word, the user name and the 

password will be queried prior 

to accessing the Control IP 4. 

The user will remain logged on 

until the browser is closed.

Three access security setting 

categories are available:

1.  No Administrator name, 

no User name:

 Everybody 

has full access to all func-

tions.

2.  Only Administrator name:

 

Everybody has access 

to the website, is able to 

switch manually and oper-

ate the timer switch. Only 

the “admin” is able to per-

form network settings and 

configuration.

3.  Administrator name and 

User name:

 “user” and 

“admin” have access to 

the website and are able to 

switch manually. However, 

the network settings, the 

timer switch settings and 

the configuration can only 

be performed by “admin”.

You can give the four outputs 

individual names. These names 

will then be displayed in the 

menu bar. 

If you wish, you can switch the 

automatic time synchronisation 

function (H) on.

In order to do so, you must 

enter the “Gateway” (Fig. 1, D) 

and “DNS server” (Fig. 1, E) 

information in the “Network” 

menu.

The configuration is stored by 

pressing “Save”.

Configuration

Settings

Summary of Contents for Control IP 4

Page 1: ...Control IP 4 Operating instructions GB Technical Support 49 2355 82 111 technical support rutenbeck de Commercial Support 49 2355 82 137 commercial support rutenbeck de ...

Page 2: ...overview Device overview Buttons for manual switching LED for activity To the 230 V power supply Network connection Temperature sensor connection LED for link External buttons for manual switching Switch outputs ...

Page 3: ...times can be individually selected for each switch output The Control IP 4 automatically obtains the time required for the switch functions from the europe pool info org server using the Simple Network Time Protocol SNTP and providing that the server can be reached is then compared each hour The current temperature can be displayed providing that a tem perature sensor is connected the network prop...

Page 4: ...y only be per formed by authorised electricians Risk to life from electric current Ensure that the power supply is disconnected before performing any assembly work Please observe the permissible operating temperature do not use the Control IP 4 directly next to devices that generate a high amount of heat e g dimmer Ensure that the device is only used indoors Installation Installation Notice ...

Page 5: ...Settings 5 Network settings without DHCP server Settings Figure 1 F A B C D E ...

Page 6: ...voltage 4 The Control IP 4 can now be accessed via the address http 192 168 0 3 or http TCRIP4 factory setting 5 Select the Network menu in the menu bar Fig 1 A 6 Select an individual Net work name in order to be able to call up the Control IP 4 directly 7 Modify the IP address of the Control IP 4 to suit your own needs 8 The configuration is stored by pressing Save Network settings without DHCP s...

Page 7: ...30 V mains voltage 4 The Control IP 4 can now be accessed via the address http 192 168 0 3 or http TCRIP4 factory setting 5 Select the Network menu in the menu bar Fig 1 A 6 Select an individual Net work name in order to be able to call up the Control IP 4 directly 7 Now activate the DHCP client Fig 1 B 8 A free IP address is now assigned to the Control IP 4 Network settings with DHCP server Setti...

Page 8: ...8 Settings Configuration Settings H I Figure 2 G ...

Page 9: ...e website is able to switch manually and oper ate the timer switch Only the admin is able to per form network settings and configuration 3 Administrator name and User name user and admin have access to the website and are able to switch manually However the network settings the timer switch settings and the configuration can only be performed by admin You can give the four outputs individual names...

Page 10: ... the outputs flash after three seconds and the factory settings are loaded Settings Buttons Operating elements LEDs The Control IP 4 outputs can be switched via the buttons located directly on the device the installed buttons or via the Control IP 4 website 1 4 Switches the connected device on off restores the factory settings see above 1 4 Switching state of the device illuminated when switched o...

Page 11: ...Switching 11 Impuls mode Switching Figure 3 K J ...

Page 12: ... switches the output off The impulse period commences when the Send field is clicked The time at which the Impulse activated notification is con firmed with OK has no effect on the impulse period The output is switched off once the period has elapsed The Control IP 4 acts converse ly when an out impulse is sent when the output is switched off The current state of the respec tive output is displaye...

Page 13: ...Switching 13 Time switch function Switching Figure 4 ...

Page 14: ...from Monday to Friday One off switching processes can also be applied for set dates The company s lighting for the stairs is connected to switch output 2 The court lighting is connected to switch output 3 The user can also switch the lighting on outside of the stipu lated times by using the buttons or via the website Fig 4 H Where necessary the output can also be put into impulse mode as described...

Page 15: ...is saved in the Control IP 4 by pressing the Save system time button It is updated and is accurate to one second In order to prevent unnecessary network load the Control IP 4 time is only updated on the screen display every 30 sec onds The internal clock of the ICP IP 4 will continue to run for approx four days after being discon nected from the mains Time switch function Switching ...

Page 16: ...ion Outputs off network off Outputs on network on Timer Power reserve Power deviation Technical data 72 x 90 x 65 mm PC 210 g Light grey similar to RAL 7035 IP20 according to DIN EN 60529 20 to 55 C 25 to 70 C 100 240 V AC 50 60 Hz max 230 V AC 50 60 Hz 10 A ohmic load cos ϕ 1 max 230 V AC 50 60 Hz 7 A inductive load cos ϕ 0 4 approx 1 W approx 3 5 W approx 4 days following disconnection from the ...

Page 17: ...ength Extension Temperature range Temperature range 25 C 25 C 50 C B value RJ45 10 Mbit s 700 802 201 0 6 m to a maximum of 10 m 25 to 55 C resolution 1 C 86 4 kΩ 10 kΩ 4 1 kΩ 3 435 K 1 Technical data Control IP 4 700 802 610 Operating instructions 293 656_GB Temperature sensor 700 802 201 Scope of delivery Accessories optional ...

Page 18: ...directives 2014 30 EU 2014 35 EU 2011 65 EU The complete Declaration of Conformity is available in the Download Section at www rutenbeck com The adjacent symbol indicates separate waste collection for electrical and elec tronic devices In accordance with EU directives all electrical and electronic de vices with this symbol must be disposed in the corresponding separate waste collections and not in...

Page 19: ...Notices 19 Notices ...

Page 20: ...3 58579 Schalksmühle Germany Phone 49 0 23 55 82 0 Fax 49 0 23 55 82 105 www rutenbeck de mail rutenbeck de Wilhelm Rutenbeck GmbH Co KG 293 656_GB 700 802 610 Rut047 Stand 04 19 Subject to technical modifications ...

Reviews: