background image

auto mode

Auto mode is a useful way to let the machine itself take control and react to any pollu-
tants that it senses. It regulates the fan speed automatically so that when the ambient
air is clean the fan turns slowly, reducing noise and saving energy. If the air quality is
poor it will turn the fan speed to a suitable level to clean the air quickly and then
reduce the speed when cleaner to maintain the cleanliness.
To select this mode press the          button until the       flashes on the LCD display.
Press          to confirm. The display will show the       to show that this mode is set.
You can also select this function using the remote control. Pressing the 

AUTO

button

will turn this mode on.

Auto mode relies on the product’s two sensors to detect pollutants. The unit will
determine the quality of the air and display this on the LCD display.

dust sensor

The dust sensor is located within the main body, behind the 
front panel and just above the filters on the right hand side.
This sensor will detect the quantity of particles in the air to 
determine the air quality. To ensure this works effectively it 

 must be cleaned regularly (see 

care and maintenance

 and you should ensure there are no blockages  
 preventing air from entering this chamber.

odour sensor

The odour sensor is located to the left of the 
LCD display. This detects odour molecules and traces of 
chemical and organic compounds in the atmosphere. 
Do not block the openings.

9

MODE

A

A

SET

To change the fan speed press the          button until the      flashes on the LCD 
display. Then press          until your required speed is chosen. You will see numbers 
to the right of the     . These numbers relate to the speed of the fan.
Alternatively if you use the remote control, press the 

FAN SPEED

button until your

required fan speed is selected. The Air Purifier at maximum fan speed filters 5 times the
air volume of an average room, per hour (68m³).

MODE

SET

dust

sensor

cover

own)

MODE

SET

TIMER -

TIMER +

ON/OFF

MODE

SET

TIMER -

TIMER +

odour 

sensor

ountain

BREEZE

C L E A N   A I R

Y

changing the fan speed

our air purifier has four fan speeds. It is recommended you use speed 1 at night as

this is very quiet. During day to day operation you should use fan speed two or three
and for very dirty and polluted rooms use fan speed four.
The faster the fan speed the more air in the room gets filtered.

Summary of Contents for Mountain breeze 12746

Page 1: ...air puri er instructions and guarantee model 12746 ountain BREEZE C L E A N A I R...

Page 2: ...air intakes odour sensor remote control sensor main body front body ountain BREEZE C L E A N A I R ountain BREEZE...

Page 3: ...hium battery not shown battery life preserving tag battery life preserving tag battery removal clips battery removal clips MODE SET TIMER TIMER MODE SET TIMER TIMER ON OFF xxxxxxxx xxxxx xxxxxxxxx act...

Page 4: ...ny objects into the air intake or outlet openings 10 Do not operate the air puri er near a stove or heater 11 Do not operate the air puri er in areas where petrol paint or other ammable liquids or gas...

Page 5: ...enlarged 1 To remove the outer cover push in the tabs at the base as shown on insert below Tabs push inwards 2 How to remove the battery tag pull up 5 ountain BREEZE C L E A N A I R...

Page 6: ...Route the cable so it doesn t overhang and can t be tripped over or caught 8 Put the plug into the power socket switch the socket on if it s switchable LCD display panel Your air puri er has many func...

Page 7: ...ill automatically enter this mode the next time the button is pressed unless the unit has been unplugged in between use The button on the remote control can be pressed instead and this has the same e...

Page 8: ...give optimum ltration e ciency combined with maximum lter lifespan Do not swap their locations about The ltration system is the heart of your air puri er and you must maintain the lters properly to e...

Page 9: ...ity To ensure this works e ectively it must be cleaned regularly see care and maintenance and you should ensure there are no blockages preventing air from entering this chamber odour sensor The odour...

Page 10: ...ical reaction that decomposes them If you turn the sterilisation mode on whilst the unit is in Auto mode it will exit Auto mode and the fan speed will come on at its previous level 10 MODE SET air qua...

Page 11: ...and buttons to select the hour and press The minutes part of the time will start ashing and again use the and buttons to select the minutes Press to con rm At this point you will notice the appear to...

Page 12: ...r in water or allow water to enter the air purifier housing as this could create an electric shock hazard filter maintenance It is vitally important that you maintain your lters in accordance with our...

Page 13: ...both metal ends and rotate 90 degrees towards from you Once rotated the tube becomes unlocked and can easily be pulled towards you To replace a tube grip on the metal ends and rotate 90 degrees away f...

Page 14: ...uitable electricity supply or dismantled or interfered with in any way or damaged through dropping or misuse Under this guarantee we undertake to repair or replace free of charge any parts found to be...

Reviews: