13

To check whether the activated carbon filter needs replacing you should 
hold it up to the light. If you can see light coming through then it has some 
life left; if you can’t see any light coming through then the filter is clogged up and

needs replacement. To replace the filter just pull it out of position using the tab provided 

and fit a replacement part into place, paying attention to fit it the correct way around. The front has

FRONT

clearly marked on the top of the filter. The Carbon filter may last  between 3 and 6 months 

The sterilisation mesh is permanent and will never need replacement. However with
prolonged use it may become a little dusty. If it looks dusty you should remove the
three UV tubes and gently vacuum using a soft tipped brush attachment. Do not knock
the surface of the filter or it may damage.

UV tubes

The UV tubes need replacement from time to time. The LCD screen will alert you to a
faulty UV tube by displaying one or more of the following icon.

corresponds to the top tube,     to the middle and     to the lowest tube so you can

easily locate the faulty tube.
To replace a tube, grip both metal ends and rotate 90 degrees towards from you.
Once rotated the tube becomes unlocked and can easily be pulled towards you.
To replace a tube grip on the metal ends, and rotate 90 degrees away from you. It will
click into place when correctly fitted.
Never rotate the tube by gripping the glass as this may cause injury.
Your air purifier has been fitted with safety devices so the tubes cannot operate with-
out the front cover or HEPA filter in place. Never disable these safety switches.
The tubes are UV-A type and replacements can be ordered.

dust sensor

The dust sensor is located in the inner body, just above the filters. This should be
cleaned once a month for optimum performance.
Firstly remove the dust sensor cover and wipe the lens using a cotton wool bud.

UV1

UV2

UV3

ordering spare parts

Spare parts can be ordered from Salton via our website 

www.salton.com.au

 

or by contacting our service department on Freecall 1800 427 842. Please quote the
following when ordering your replacement filters:

MBSP1  Replacement Hepa and Pre-filter
MBSP2  2x Replacement activated Carbon filters
MBSP3 3x 

Replacement 

UV 

tubes

MBSP4  Replacement filter pack (HEPA + 2x Pre filter + 2x Carbon filter)
 

if there is cigarette smoke in the house. UVA tubes last for around 10,000 hours (to 50% failure). 

ountain

BREEZE

C L E A N   A I R

Summary of Contents for Mountain breeze 12746

Page 1: ...air puri er instructions and guarantee model 12746 ountain BREEZE C L E A N A I R...

Page 2: ...air intakes odour sensor remote control sensor main body front body ountain BREEZE C L E A N A I R ountain BREEZE...

Page 3: ...hium battery not shown battery life preserving tag battery life preserving tag battery removal clips battery removal clips MODE SET TIMER TIMER MODE SET TIMER TIMER ON OFF xxxxxxxx xxxxx xxxxxxxxx act...

Page 4: ...ny objects into the air intake or outlet openings 10 Do not operate the air puri er near a stove or heater 11 Do not operate the air puri er in areas where petrol paint or other ammable liquids or gas...

Page 5: ...enlarged 1 To remove the outer cover push in the tabs at the base as shown on insert below Tabs push inwards 2 How to remove the battery tag pull up 5 ountain BREEZE C L E A N A I R...

Page 6: ...Route the cable so it doesn t overhang and can t be tripped over or caught 8 Put the plug into the power socket switch the socket on if it s switchable LCD display panel Your air puri er has many func...

Page 7: ...ill automatically enter this mode the next time the button is pressed unless the unit has been unplugged in between use The button on the remote control can be pressed instead and this has the same e...

Page 8: ...give optimum ltration e ciency combined with maximum lter lifespan Do not swap their locations about The ltration system is the heart of your air puri er and you must maintain the lters properly to e...

Page 9: ...ity To ensure this works e ectively it must be cleaned regularly see care and maintenance and you should ensure there are no blockages preventing air from entering this chamber odour sensor The odour...

Page 10: ...ical reaction that decomposes them If you turn the sterilisation mode on whilst the unit is in Auto mode it will exit Auto mode and the fan speed will come on at its previous level 10 MODE SET air qua...

Page 11: ...and buttons to select the hour and press The minutes part of the time will start ashing and again use the and buttons to select the minutes Press to con rm At this point you will notice the appear to...

Page 12: ...r in water or allow water to enter the air purifier housing as this could create an electric shock hazard filter maintenance It is vitally important that you maintain your lters in accordance with our...

Page 13: ...both metal ends and rotate 90 degrees towards from you Once rotated the tube becomes unlocked and can easily be pulled towards you To replace a tube grip on the metal ends and rotate 90 degrees away f...

Page 14: ...uitable electricity supply or dismantled or interfered with in any way or damaged through dropping or misuse Under this guarantee we undertake to repair or replace free of charge any parts found to be...

Reviews: