Ensure that there is free and unobstructed airflow around the
fixture. Provide a minimum clearance of 100 mm (4 in.) around
fans and air vents.
Do not illuminate surfaces within 200 mm (7.9 ins.) of the fixture.
Do not attempt to bypass thermostatic switches or fuses.
Do not stick filters, masks or other materials onto any optical
component.
Protection from eye injury
Do not stare directly into the light output. Ensure that persons
are not looking directly into the LEDs when the product lights up
suddenly. This can happen when power is applied, when the
product receives a DMX signal, or when certain control menu
items are selected.
Do not look at the light output with magnifiers, telescopes,
binoculars or similar optical instruments that may concentrate
the light output.
To minimize the risk of eye irritation or injury, disconnect the
fixture from power at all times when the fixture is not in use, and
provide well-lit conditions to reduce the pupil diameter of anyone
working on or near the fixture.
Protection from injury
Fasten the fixture securely to a fixed surface or structure when in
use. The fixture is not portable when installed.
Ensure that any supporting structure and/or hardware used can
hold at least 10 times the weight of all the devices they support.
If suspending from a rigging structure, fasten the fixture to a
rigging clamp. Do not use safety cables as the primary means of
support.
If the fixture is installed in a location where it may cause injury or
damage if it falls, install as directed in this manual a secondary
attachment such as a safety cable that will hold the fixture if a
primary attachment fails. The secondary attachment must be
approved by an official body such as TÜV as a safety
attachment for the weight that it secures, must comply with EN
60598-2-17 Section 17.6.6 and must be capable of bearing a