RUSH MH 5 Profile User Manual
7
The supplied power input cable is rated 6 A and can safely
supply only one fixture with mains power. Do not connect any
device to the fixture’s MAINS OUT connector when using this
cable. If you replace this cable and also use the replacement
cable to supply only one fixture with mains power, the
replacement cable must also be rated 6 A minimum, have three
conductors 18 AWG or 0.75 mm² minimum conductor size, have
an outer cable diameter of 6 - 15 mm (0.2 - 0.6 in.) and be
temperature-rated to suit the application. In the USA and
Canada the cable must be UL listed, type SJT or equivalent. In
the EU the cable must be type H05VV-F or equivalent.
To connect fixtures to mains power in a chain, you must first
obtain 14 AWG or 1.5 mm
2
power input and throughput cables
that are 16 A rated and temperature-rated to suit the application.
In the USA and Canada the cables must be UL-listed, type SJT
or equivalent. In the EU the cables must be type H05VV-F or
equivalent. Suitable cables with Neutrik PowerCon connectors
are available from Martin™ (see ‘Accessories’ on page 41). If
you use these cables, you can connect fixtures to power in a
linked chain, MAINS OUT throughput socket to MAINS IN input
socket, but do not link more than:
•
eight (8) RUSH MH 5 fixtures in total at 100-120 V, or
•
eighteen (18) RUSH MH 5 fixtures in total at 200-240 V.
The voltage and frequency at the MAINS OUT socket are the
same as the voltage and frequency applied to the MAINS IN
socket. Only connect devices to the MAINS OUT socket that
accept this voltage and frequency.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (T
a
)
exceeds 40° C (104° F).
The surface of the product casing can reach up to 60° C
(140° F) during operation. Avoid contact by persons and
materials. Allow the fixture to cool for at least 10 minutes before
handling.
Keep flammable materials well away from the fixture. Keep all
combustible materials (e.g. fabric, wood, paper) at least 100 mm
(4 in.) away from the fixture head.