appropriate. This includes a thermostat and a self-resetable thermal switch to control
heating elements. The thermostat takes over the air temperature and controls the
surrounding temperature. The fan motor is not controlled by the thermostat and continues
to operate when the thermostat interrupts the heating element (in the case of VULCANO
200S models). The fan motor is controlled by the thermostat and continues to operate
when the thermostat interrupts the heating element (in the case of the VULCANO 300S
model), again the self-resetting heat switch will turn off the heating system to ensure
safety in case of overheating.
2.2 When using the heater for the first time, you may notice a slight smoke emission.
This is normal and disappears after a short period of time. The heating element is made
of stainless steel and has been covered with protective oil from the factory. The smoke
is caused by the remaining oil when it heats up.
3. SPECIAL SAFETY REGULATIONS
3.1
Before use, please check the marking on the power cord. Depending on the type of
power cord, this appliance can be used in different environmental conditions
Type
You can use the device in
Do not use in
H07RN-F
household
(household),
warehouses
and
workshops,
construction
sites
or
greenhouses
H05RN-F
household
(household),
warehouses and workshops or
greenhouses
construction sites
3.2
When using household appliances, basic precautions, including those below, will
always be followed
3.2.1 The air heater is not suitable for outdoor use in humid weather, in bathrooms or in
other humid environments.
Summary of Contents for VULCANO 200S
Page 1: ...MANUAL DE UTILIZARE RURIS VULCANO 200S 300S ...
Page 22: ...EN ELECTRIC HEATER RURIS VULCANO 200S 300S USER MANUAL ...
Page 39: ...BG РЪКОВОДСТВО ЗА EЛЕКТРИЧЕСКА ДУХАЛКА RURIS VULCANO 200S 300S ...
Page 52: ...BG 14 10 ПОТРЕБИТЕЛСКА ДИАГРАМА ...
Page 60: ...SRB Električna grijalica RURIS VULCANO 200S 300S ...